Skip to main content
Back

with gas treatment system MAXISYSTEM ST | M05100210

with gas treatment system MAXISYSTEM ST

manufactured goods

  • automatic sensor regeneration via fresh air valve allows for convenient long-term measurements of up to 12 hours
  • optionally with humidity sensor for sensor protection
  • smart system protection by means of continuous monitoring of fresh air valve, heated line, cooler and humidity sensor
  • particularly suitable for industrial applications due to the robust, light.weight design (7.5 kg)
  • Large range of probes: Heated line including draft and flue gas temperature, - Modular probe system, high-temperature probes
  • automatic zero point for convenient and fast measurement preparation

Gas treatment system specially for mobile applications. Whenever high-precision gas analysis is required where the flue gas may contain pollution and condensate, MAXISYSTEM ST is the system of choice. In the analysis of highly water-soluble gases such as NO2 and SO2, MAXISYSTEM ST must be used in order to be able to obtain reliable measurement results.

The modular measurement concept allows to use the corresponding flue gas analyser MULTILYZER STx as a "stand-alone device" or in conjunction with MAXISYSTEM ST. With the integrated temperature controller, the temperature of the heated line can be optimally adjusted to the application between 100 °C and 180 °C. Flue gas analysis, draft/differential pressure and flue gas temperature are directly measured. Efficiency, flue gas loss and dew point are calculated in real time. The operating state of the measuring device can be checked via the status indication of the heated line and the gas cooler. The condensate outlet integrated in the housing reliably discharges condensate. MAXISYSTEM ST is designed for quasi-continuous operation with an operating time of up to 12 hours.

Einsatzmedien

Operating temperature range
Ambient:
5/40 °C
Storage:
-20/+50 °C
Gas outlet dew point:
Factory setting:
5 °C
heated sampling line
adjustable:
100/180 °C
alarm threshold
± 3 K around dew point of gas cooler or temperature of sampling line
nominal cooling capacity
  72 kJ/h   at 25 °C
Supply voltage
AC 230 V, 50/60 Hz
wetted parts
Stainless steel, PTFE, PVDF, Silikon, fluoroelastomer, PA
Housing
W x H x D:
420 x 350 x 220 mm
Weight:
  7.5 kg ( )
Degree of protection:
IP 42 (EN 60529)
Interface
Bluetooth®

Modular probe system
Abb.
Bezeichnung
 Base handle AWS-B  compensation line 2.4 m, with condensate filter cartridge KFP, with draft
Base handle AWS-B compensation line 2.4 m, with condensate filter cartridge KFP, with draft | 510921
Condensate filter cartridges KFP
Abb.
Bezeichnung
 condensate filter cartridge KFP
condensate filter cartridge KFP | 500190
Flue gas probes
Abb.
Bezeichnung
 high-temperature flue gas combination probe AKS-HT  up to 1000 °C, length 1500 mm
high-temperature flue gas combination probe AKS-HT up to 1000 °C, length 1500 mm | 500273-1
Thermal printer EUROprinter
Abb.
Bezeichnung
 Thermal printer EUROprinter II
Thermal printer EUROprinter II | 524340
 Thermal printer EUROprinter II IR-BLE
Thermal printer EUROprinter II IR-BLE | 524346
Humidity sensors
Abb.
Bezeichnung
 humidity sensor FES-MX
humidity sensor FES-MX | 511180
Analysis lines
Abb.
Bezeichnung
 Sampling line ENL-MX  heated, length 3m
Sampling line ENL-MX heated, length 3m | 524437
Transport systems/cases
Abb.
Bezeichnung
 Carrying bag   for MAXISYSTEM ST
Carrying bag for MAXISYSTEM ST | 524651
Modular high-temperature probe system
Abb.
Bezeichnung
 Base handle AWS-BHT  compensation line 2.4 m, with condensate filter cartridge KFP, with draft
Base handle AWS-BHT compensation line 2.4 m, with condensate filter cartridge KFP, with draft | 510821
 Base handle AWS-BHT  Compensation line 5 m, with condensate filter cartridge KFP, with draft
Base handle AWS-BHT Compensation line 5 m, with condensate filter cartridge KFP, with draft | 510831