Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement

Afriso Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement
Afriso Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement
Afriso Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement
Afriso Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement
Data sheet Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement
Afriso Data sheet Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement

Versions

Type Connection Measuring range Part no. Remember
DeltaFox® DMU 10 D 2x G⅛B female thread 0/6 mbar 31861
DeltaFox® DMU 10 D 2x G⅛B female thread 0/10 mbar 31862
DeltaFox® DMU 10 D 2x G⅛B female thread 0/25 mbar 31863
DeltaFox® DMU 10 D 2x G⅛B female thread 0/40 mbar 31864
DeltaFox® DMU 10 D 2x G⅛B female thread 0/60 mbar 31865
DeltaFox® DMU 10 D 2x G⅛B female thread 0/100 mbar 31866
DeltaFox® DMU 10 D 2x G⅛B female thread 0/160 mbar 31867
DeltaFox® DMU 10 D 2x G⅛B female thread 0/250 mbar 31868
DeltaFox® DMU 10 D 2x G⅛B female thread 0/400 mbar 31869
DeltaFox® DMU 10 D 2x G⅛B female thread 0/600 mbar 31870
DeltaFox® DMU 10 D 2x G⅛B female thread 0/1 bar 31871

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement Data sheet PDF
Afriso Data sheet Pressure transducers DeltaFox® DMU 10 D Version for differential pressure measurement
Electronic pressure measurement - pressure transducers DMU series Product range industrial technology PDF
Afriso Electronic pressure measurement - pressure transducers DMU series
Enquiry pressure transducers DMU Pressure measuring instruments PDF
Afriso Enquiry pressure transducers DMU
Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
≤ ± 2 % FSO
≤ ± 1 % FSO
≤ ± 0.35 % FSO
Measuring range
See ordering table
Overpressure safety
100 mbar
350 mbar
1,000 mbar
3,000 mbar
≤ 0/25 mbar:
200 mbar
Operating temperature range
Medium:
-25/+125 °C
Ambient:
-25/+85 °C
Storage:
-40/+100 °C
Temperature error band
≤ ± 2 % FSO In compensated range 0/60 °C
≤ 0/25 mbar:
≤ ± 1.5 % FSO In compensated range 0/60 °C
≤ 0/250 mbar:
≤ ± 1 % FSO In compensated range 0/60 °C
> 0/250 mbar:
≤ ± 0.5 % FSO In compensated range 0/60 °C
Dynamic characteristics
Response time:
< 5 ms
Process connection
2x G⅛B female thread
Material
Housing:
Aluminium, eloxed, silver
Pressure connection:
Aluminium
Seal:
PUR glued
Supply voltage
DC 8 – 32 V
Output signal
2-wire, 4–20 mA
Load
R<sub>Max</sub> = [(UB – UB<sub>Min</sub>)/0.02 A] Ω
Current input
< 25 mA
Electrical protection
Short circuit proof and protected against reverse polarity
Electrical connection
Connector and junction box as per ISO 4400 (DIN 43650-A)
Degree of protection
IP65 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU

Options

  • Other process connections
  • Other electrical connections
wiring diagram
wiring diagram
Afriso