Measuring system MEA 3000 61090
Measuring system MEA 3300 61091

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Measuring system MEA 3000 / 3300 for exhaust gas cleaning systems (scrubbers) Data sheet PDF
Afriso Data sheet Measuring system MEA 3000 / 3300 for exhaust gas cleaning systems (scrubbers)
Maritime emission measurement (MARPOL regulation) with measuring system MEA 2000 Stationary gas analysis PDF
Afriso Maritime emission measurement (MARPOL regulation) with measuring system MEA 2000
Enquiry gas analysis Stationary gas analysis PDF
Afriso Enquiry gas analysis
The MEA 3000 / 3300 measuring system for continuous emission monitoring (CEMS) from AFRISO is based on proven NDIR measurement technology. This measurement technology allows for reliable measuring and monitoring of the limit values for SO2, CO2 and NOX (optional) specified by the IMO. The accurate complete system allows for simultaneous monitoring of multiple measuring points and different measured values. The system's space-saving and robust design make it easy to install or retrofit on site. Due to the innovative filter technology, a practical calibration system and a self-cleaning probe, the system requires very little maintenance.
Measuring range
Flue gas temperature:
0/500 °C
SO2:
0/250 to 0/500 ppm
CO2:
0/20 Vol.-%
Measuring principle
NDIR measurement technology
Non-dispersive infrared technology,
Extractive measurement (cold/dry)
Operating temperature range
Operation:
5/35 °C, with fan
5/45 °C, with air conditioning system
Storage:
2/60 °C
Supply voltage
AC 100 – 240 V, 50 – 60 Hz
Power input
Approx. 1,200 VA without heated line,
Additionally 100 W/m for the heated line
Analogue output
2 x 4–20 mA
Switching outputs
4 voltage-free contacts for status messages
Enclosure
Robust, metal analyser control cabinet
W x H x D:
750 x 1,100 x 640 mm
Weight
Approx. 110 kg
Degree of protection
IP54 (EN 60529)

Options

  • Other gases on request