Measuring ranges (measured values)
Flue gas temperature/differential temperature
0/1,150 °C
Air temperature/combustion air temperature
-20/+200 °C
Pitot
0.5/70 m/s
O<sub>2</sub> measurement
0/21 Vol.-%
CO<sub>H2</sub> measurement
Nominal:
0/4,000 ppm
Maximum:
0/10,000 ppm
Additional technical specifications
Indication (calculated values)
CO<sub>2</sub>, CO<sub>Undiluted (air-free)</sub>, Lambda<sub/>, Dew point<sub/>, Eta efficiency, Flue gas losses qA
Operating temperature range
Ambient:
0/40 °C
Storage:
-20/+50 °C
Weight (measuring instrument)
500 g
Dimensions
W x H x D:
80 x 218 x 44 mm
Degree of protection
IP 42 (EN 60529)
Display
4.3 "
Connections
Draft/pressure:
∅ 7/∅ 8 mm
Gas:
∅ 8 mm
Supply voltage
Lithium-ion battery (3.6 V/5,000 mAh)
Power supply unit (USB-C)
Battery or mains
Hours of operation (eco mode)
12 Stunden
Data memory
10,000 Messungen
Scope of delivery
-
Flue gas analyser EUROLYZER<sup>®</sup> S1
-
Calibration report
-
5 x Infiltec fine filter
-
Condensate filter cartridge KFP
-
Base handle AWS-B for interchangeable probes
-
Ambient air probe TFB-UL 50-1