Connection
Stainless steel 316 Ti/316 L, bottom
G½B, SW22 (EN 837-1/7.3)
Electrical connection
Junction box
Measuring element
Bourdon tube, stainless steel 316 Ti/316 L
≤ 60 bar:
"C" type tube
> 60 bar:
Helical tube
Movement
Stainless steel
Dial
Aluminium, white
Scaling black
Pointer
Aluminium, black
Housing
Stainless steel 304, with blow-out
Bayonet type bezel
Stainless steel 304
Window
Plastic (Makrolon), with contact adjustment lock
Inductive contact (IK)
Supply voltage
DC 5 – 25 V
Current input
≥ 2.1 mA
Switching accuracy
Approx. 0.5 % of full scale value
Operating temperature range
-20/+70 °C or corresponding to the respective measuring instruments
Adjustment range
5–95 % measuring range of gauge
Options
-
Contact systems with safety integrity level SIL 2
Magnetic spring contact (MK)
Supply voltage
Max. AC/DC 250 V
Making current and breaking current
Max. 1 A
Continuous current
Max. 0.6 A
Switch rating
Max. 50 VA, max. 30 W
Contact
Ag80 Ni20 Au 10 μm
Switching accuracy
Approx. 2–5 % of full scale value
Operating temperature range
-20/+70 °C or corresponding to the respective measuring instruments
Adjustment range
5–95 % measuring range of gauge