Images 4
Back
Pressure transducers DMU 30 | DMU_30111220401
Pressure transducers DMU 30 Industrial version
manufactured goods
| Measuring range | 0/400 bar |
|---|---|
| Connection | G½B |
| Connection | EN 837-1/7.3 |
| Electrical connection | M12 x 1, 4-pin |
| Part no. | DMU 30111220401 |
- for pressure ranges up to 1,000 bar
- suitable for high overloads
- insensitive to pressure peaks
- Ex version (optional)
For electronic pressure measurement in machines and systems with technical gases (e.g. oxygen, oil-free, grease-free) and for use in hydrogen applications.
Pressure transducers convert physical pressure into an electrical signal proportional to the pressure. DMU 30 is equipped with a welded stainless steel measuring cell.
- Measuring accuracy
- Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
- < ± 0.5 % FSO
- Long-term stability
- ≤ ± 0.2 % FSO/Jahr ≤ ± at reference conditions
- Measuring range:
- 0/400 bar
- Overpressure safety
- > 16 bar: 2 x FS
- Burst pressure
- < 600 bar: at least 5 x FS
- Vacuum resistance:
- unlimited
- Operating temperature range
- Medium:
- -40/+125 °C
- Ambient:
- -40/+100 °C
- Storage:
- -40/+85 °C
- Temperature error band
- ≤ ± 0.2 % FSO/10 K ≤ ± In compensated range -25/+85 °C
- dynamic characteristics
- Response time:
- ≤ 10 ms
- Process connection
- G½B (EN 837-1/7.3)
- material
- Housing:
- Stainless steel 316 L
- pressure connection:
- Stainless steel 316 L
- diaphragm:
- Stainless steel 316 L
- Seal:
- without (welded)
- Degree of cleanliness:
- oil- and grease-free version, based on ISO 15001
- Residual particles:
- no particles > 100 µm (with reference to 10 dm2)
- Residual grease:
- Residual grease content < 0.2 mg/dm2
- Supply voltage
- Standard version: DC 8 − 32 V
- Output signal
- 4–20 mA, 2-wire
- Load
- Rmax = [(UB – UBmin)/0.02 A] Ω
- Current input
- < 25 mA
- electrical protection
- short circuit proof and protected against reverse polarity
- Electrical connection
- M12 x 1, 4-pin
- Degree of protection
- IP 67 (EN 60529)
- CE conformity
- EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU
Pressure Equipment Directive 2014/68/EU