Images 3
Back
Pressure transducers HydroFox® DMU 08 T | 31566T0070
Pressure transducers HydroFox® DMU 08 T Level probe
manufactured goods
| Measuring range | 0/6 bar |
|---|---|
| Part no. | 31566T0070 |
- with integrated temperature measurement
- compact and sturdy stainless steel design
- integrated overvoltage protection
- special calibration for all standard pressure units possible
For electronic, continuous level measurement, e.g. in wells, drilling holes, water, containers or in waste water systems. Suitable for groundwater, waste water (with optional FEP cable), diesel fuel and fuel oil.
Pressure transducers HydroFox® DMU 08 convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 08 uses a piezo-resistive silicon measuring cell.
- Measuring accuracy
- Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
- > 0/400 mbar < ± 0.35 % FSO
- Measuring range
- 0/6 bar
- Operating temperature range
- Medium:
- -10/+70 °C
- Ambient:
- -10/+70 °C
- Storage:
- -25/+70 °C
- Temperature error band
- > 400 mbar: ≤ ± 0.75 % FSO ≤ ± In compensated range 0/70 °C
- dynamic characteristics
- Response time:
- ≤ 10 ms
- Probe
- L x ⌀:
- 129 x 26.5 mm
- material
- Housing:
- Stainless steel 316 L
- diaphragm:
- Stainless steel 316 L
- seals:
- FKM (Viton)
- cable:
- PUR
- pressure transmission liquid
- Silicone oil
- Supply voltage
- pressure:
- DC 12 − 30 V
- temperature:
- DC 10 − 30 V
- Output signal
- 4–20 mA, 2-wire
- Load
- Rmax = [(UB – UBmin)/0.02 A] Ω
- Current input
- < 25 mA
- electrical protection
- short circuit proof and protected against reverse polarity
- Electrical connection
- PUR cable with integrated breather tube for reference to the ambient atmospheric pressure
- Cable length:
- 5 m
- Degree of protection:
- IP 68 (EN 60529)
- CE conformity
- EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU