Alarm unit for separators WGA 01 D

 ANW 92970 92980  ANW 92970 92980
 ANW 92970 92980 <div class="gallery-information"> <b>Legend:</b> <ol> <li>Oil</li> <li>Water</li> <li>Sand / sludge</li> </ol> </div>
 92970 object_image_76625imagemain_en
 VOR 19580 19640
 VOR 19600 19660
 SAL 92980
 SAL 19680
 DRU 92970 92980
 ANW 92970 92980
Data sheet Alarm unit for separators WGA 01 D
AFRISO Data sheet Alarm unit for separators WGA 01 D

Versions

Part no. Remember
Alarm unit for separators WGA 01 D incl. probe WGA-ES4 (layer thickness) 53409
Alarm unit for separators WGA 01 D 53409A
Probe WGA-R6 for overflow alarm 53419
Probe WGA-ES4 for layer thickness alarm 53418
Probe WGA-ES8 for sludge alarm 53399

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Alarm unit for separators WGA 01 D Data sheet PDF
AFRISO Data sheet Alarm unit for separators WGA 01 D
Alarm unit for separators WGA 01 D Operating instructions PDF
AFRISO Alarm unit for separators WGA 01 D
Alarm units WGA for separators Alarm units PDF
AFRISO Alarm units WGA for separators
WGA 01 D consists of a control unit with LC display and a capacitance probe (WGA-ES4) to monitor the layer thickness of oil or petrol layers. The PTC thermistor probe WGAR6 for monitoring the maximum level (overflow alarm) and/or the ultrasonic sludge probe WGA-ES8 for monitoring impermissible sand or sludge layer can also be connected. The control unit is equipped with 2 relay outputs, visual and audible alarms as well as Test and Acknowledge buttons. The WGA-ES4 probe is mounted at least 150 mm below the constant level of the separator. As soon as the oil, petrol or grease layer reaches the critical level, the device generates an alarm signal. By installing the optional WGA-R6 probe above the constant level, you can also monitor the maximum level. The control unit monitors the probes for short circuits or line interruptions. The device automatically detects the connected probes during commissioning.
Operating temperature range
Medium:
-20/+40 °C
Ambient:
0/40 °C
Supply voltage
AC 230 V
Power input
Approx. 4 VA
Switching outputs
Relay contact:
2 voltage-free changeover contacts
Contact rating:
AC 250 V, 5 A, 100 VA
Visual indication
LC display, 3 lines
Audible alarm
Integrated piezo-buzzer, can be acknowledged
Housing
Wall mounting housing made of impact-resistant plastic (polycarbonate)
W x H x D:
175 x 125 x 75 mm
Degree of protection:
IP 65 (EN 60529)
Ex approval
Ex II (1) G [Ex ia GA] IIA
Probe WGA-ES4
Measuring principle:
Capacitance
L x ⌀:
220 x 25 mm
Cable length:
5 m
Probe WGA-ES8 (option)
Measuring principle:
Ultrasonic
W x H x D:
160 x 85 x 32 mm
Cable length:
5 m
Probe WGA-R6 (option)
Measuring principle:
PTC thermistor
L x ⌀:
100 x 22 mm
Cable length:
5 m
Connection probe – control unit
Max. 200 m
Scope of delivery
  • Control unit
  • Probe WGA-ES4

Options

  • Probe WGA-ES8
  • Probe WGA-R6