Pressure transducers HydroFox® DMU 09 level probe - for chemical applications

Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Legende: <div class="gallery-information"> <ol> <li>Junction box with pressure relief port</li> <li>Digital display unit DA 12</li> <li>Signalling device</li> <li>HydroFox<sup>®</sup> DMU09</li> </ol> </div>
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Legende: <div class="gallery-information"> <p> <strong>Anchor clamp</strong> </p> <p>Dimensions (in mm)</p> <ol> <li>Cable diameter</li> </ol> </div>
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Legende: <div class="gallery-information"> <p> <strong>Junction box with pressure relief port</strong> </p> <p>Dimensions (in mm)</p> <ol> <li>Earth</li> <li>Cable gland</li> <li>Pressure compensation element</li> </ol> </div>
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Data sheet Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Afriso Data sheet Pressure transducers HydroFox® DMU 09 level probe - for chemical applications

Versions

Type Measuring range Part no. Remember
HydroFox® DMU 09 0/40 mbar 31767
HydroFox® DMU 09 0/60 mbar 31768
HydroFox® DMU 09 0/100 mbar 31571
HydroFox® DMU 09 0/160 mbar 31572
HydroFox® DMU 09 0/200 mbar 31573
HydroFox® DMU 09 0/250 mbar 31574
HydroFox® DMU 09 0/300 mbar 31812
HydroFox® DMU 09 0/400 mbar 31575
HydroFox® DMU 09 0/600 mbar 31576
HydroFox® DMU 09 0/1 bar 31577
HydroFox® DMU 09 0/1.6 bar 31578
HydroFox® DMU 09 0/2 bar 31579
HydroFox® DMU 09 0/2.5 bar 31580
HydroFox® DMU 09 0/4 bar 31581
HydroFox® DMU 09 0/6 bar 31582
HydroFox® DMU 09 0/10 bar 31583

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Pressure transducers HydroFox® DMU 09 level probe - for chemical applications Data sheet PDF
Afriso Data sheet Pressure transducers HydroFox® DMU 09 level probe - for chemical applications
Submersible probe DMU 08, DMU 08 T, DMU 09 Operating instructions PDF
Afriso Submersible probe DMU 08, DMU 08 T, DMU 09
Probes for is areas DMU 08…Ex, DMU 09…Ex Operating instructions PDF
Afriso Probes for is areas DMU 08…Ex, DMU 09…Ex
Electronic pressure measurement - pressure transducers DMU series Product range industrial technology PDF
Afriso Electronic pressure measurement - pressure transducers DMU series
Enquiry pressure transducers DMU PDF
Afriso Enquiry pressure transducers DMU
Pressure transducers HydroFox® convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 09 uses a capacitance ceramic measuring cell.
Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
< ± 0.35 % FSO
Measuring range
See ordering table
Overpressure safety
≤ 400 mbar:
At least 15 x FS
> 400 mbar:
At least 3 x FS
Operating temperature range
Medium:
-25/+70 °C
Ambient:
-25/+70 °C
Storage:
-25/+70 °C
Dynamic characteristics
Response time:
< 200 ms
Probe
L x ⌀:
126 x 45 mm
Material
Housing:
PP
Diaphragm:
Ultra-pure ceramic (Al203 99.9 %)
Seals:
FKM (Viton)
Cable:
FEP
Supply voltage
DC 9 – 32 V
Output signal
4–20 mA, 2-wire
Load
R<sub>Max</sub> = [(UB – UB<sub>Min</sub>)/0.02 A] Ω
Current input
< 21 mA
Electrical protection
Short circuit proof and protected against reverse polarity
Electrical connection (FEP cable with integrated breather tube for reference to the ambient atmospheric pressure)
Cable length:
5 m
Degree of protection:
IP 68 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU

Options

  • Housing PVDF
  • Cable protection conduits
  • Seals made of FFKM
  • EX version (Ex II 1G or II 1/2G Ex ia IIC/IIB T4 Ga or Ga/Gb, Ex II 1D Ex ia IIIC T85°C Da)
  • Screw connector kit
  • Junction box
  • Anchor clamp
Anchor clamp
Anchor clamp
Afriso
Dimensions (in mm)
  1. Cable diameter
Junction box with pressure relief port
Junction box with pressure relief port
Afriso
Dimensions (in mm)
  1. Earth
  2. Cable gland
  3. Pressure compensation element
DMU 09 - standard version
DMU 09 - standard version
Afriso
Dimensions (in mm)
Screw connector kit
Screw connector kit
Afriso
wiring diagram
wiring diagram
Afriso
2-wire, 4-20 mA