Gas analyser BIOLYZER For discontinuous measurement

 VOR 74190 74200 74210 74230 74240 74250 object_image_64075imagemain_en
Data sheet gas analyser BIOLYZER For discontinuous measurement
AFRISO Data sheet gas analyser BIOLYZER For discontinuous measurement

Versions

Part no. Remember
Gas analyser BIOLYZER for CH4, H2S, O2, CO2 69643
Gas analyser BIOLYZER for CH4, H2S, O2 69644
Gas analyser BIOLYZER for CH4, H2S 69645
Gas analyser BIOLYZER LT for CH4, H2S, O2, CO2 69646
Gas analyser BIOLYZER LT for CH4, H2S, O2 69647
Gas analyser BIOLYZER LT for CH4, H2S 69648

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet gas analyser BIOLYZER For discontinuous measurement Data sheet PDF
AFRISO Data sheet gas analyser BIOLYZER For discontinuous measurement
Gas analyser BIOLYZER for discontinuous measurement Declaration of Conformity PDF
AFRISO Gas analyser BIOLYZER for discontinuous measurement

Gas measuring system for discontinuous, selective measurement and indication of up to four different gas components (CH4, H2S, O2 and CO2). CH4 and CO2 are detected by means of infrared technology, O2 and H2S by means of electrochemical sensors. All components are integrated in a robust wall mounting housing. BIOLYZER features an LED display, status indicators for each measurement channel as well as a lit LC display. The memory has a history function, the values can be displayed. With freely adjustable alarm thresholds and binary outputs for: active, error, calibration, alarm. The gas treatment system with all important components (gas cooler with hose pump, fine filter, aerosol filter, rotameter with needle valve, anti-detonation device) is integrated in a robust, air-flushed wall mounting housing. BIOLYZER is delivered complete with wiring, hoses, calibration and ready to be mounted.

BIOLYZER LT is suitable for simple routine checks. Version without gas cooler and load limitation for hydrogen sulphide measurements. Therefore, the standard measuring range is 0 to 1,000 ppm H2S.

Gas types/measuring ranges
Measuring intervals can be programmed for the individual gas types. Manual measurement is possible at all times.
CH4:
0/100 Vol.-%
IR double beam
CO2:
0/100 Vol.-%
IR double beam
O2:
0/25 Vol.-%
Electrochemical
H2S
H2S:
Electrochemical
BIOLYZER:
0/5,000 ppm
BIOLYZER LT:
0/1,000 ppm
Indicator
4-digit LED: Status indicators for each channel,
4-digit LED: Data memory can be read via RS 232
Communication
RS 232
1 analogue output per gas type,, output 4–20 mA, linearised, 1 analogue output per gas type,, output 4–20 mA, linearised
Data memory with history function
Operating temperature range
Ambient:
10/40 °C
Storage:
-25/+50 °C
Supply voltage
AC 230 V, 50 Hz
Optional:
AC 115 V, 60 Hz
Power input:
Max. 85 VA
Dimensions
W x H x D:
300 x 400 x 185 mm
Degree of protection
IP 54 (EN 60529)