Images 1
Back
Pressure transducers DMU 04 | 33022
Pressure transducers DMU 04 Industrial version
manufactured goods
| Measuring range | 0/160 mbar |
|---|---|
| Connection | G1B |
| Connection | DIN 3852 type E |
| Electrical connection | Connector and junction box as per ISO 4400 (DIN 43650-A) |
| Part no. | 33022 |
- DMU 04 CP/MR for hygienic processes
- small temperature error
- Options: Ex, field housing or high temperature version (up to 300 °C) and SIL 2
For applications requiring hygienic process connections, materials or processing, especially food technology, pharmaceutical and biotechnology applications.
Pressure transducers convert physical pressure into an electrical signal proportional to the pressure. DMU 4 is equipped with an oil-filled piezo-resistive silicon measuring cell. DMU 04 has safety integrity level SIL 2 (IEC 61508/61511).
- Measuring accuracy
- Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
- ≤ 0/400 mbar < ± 0.5 % FSO
- Measuring range
- 0/160 mbar
- Overpressure safety
- at least 3 x FS
- Burst pressure
- at least 5 x FS
- Operating temperature range
- Medium:
- -10/+125 °C
- Medium:
- short-term (60 min) up to 150 °C
- Ambient:
- -40/+85 °C
- Storage:
- -40/+100 °C
- Temperature error band
- < 400 mbar: ≤ ± 1.5 % FSO/10 K ≤ ± In compensated range 0/50 °C
- dynamic characteristics
- Response time:
- ≤ 10 ms
- Process connection
- G1B DIN 3852 type E with flush diaphragm
- material
- Housing:
- Stainless steel 316 L
- pressure connection:
- Stainless steel 316 L
- diaphragm:
- Stainless steel 316 L
- pressure transmission liquid
- Food oil, FDA-compliant
- Supply voltage
- DC 8 − 32 V
- Output signal
- 2-wire, 4–20 mA
- Load
- Rmax = [(UB – UBmin)/0.02 A] Ω
- Current input
- < 25 mA
- electrical protection
- short circuit proof and protected against reverse polarity
- Electrical connection
- Connector and junction box as per ISO 4400 (DIN 43650-A)
- Degree of protection
- IP 65 (EN 60529)
- CE conformity
- EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU
Pressure Equipment Directive 2014/68/EU