Images 3
HydroFox® DMU 07
Druckmessumformer für Füllstandmessung
| Connection | G1½B |
|---|---|
| Electrical connection | Connector and junction box as per ISO 4400 (DIN 43650-A) |
- flush diaphragm
- without transmission liquid
- mechanically insensitive ceramic sensor
- small temperature error
- high overpressure safety
For electronic, continuous level measurement of liquids and for pressure measurement of liquids and gases in plant construction.
Pressure transducers convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 07 uses a capacitance ceramic measuring cell.
- in-stock items
- manufactured goods
- Measuring accuracy
- Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
- < ± 0.35 % FSO
- 0/40 mbar
- Overpressure safety
- ≤ 400 mbar: at least 25 x FS
- > 400 mbar: at least 3 x FS
- Operating temperature range
- Medium:
- -40/+125 °C
- Ambient:
- -40/+85 °C
- Storage:
- -40/+100 °C
- Temperature error band
- ≤ 0.1 % FSO/10 K ≤ In compensated range -20/+80 °C
- dynamic characteristics
- Response time:
- ≤ 200 ms
- Process connection
- G1½B with flush diaphragm
- material
- Housing:
- Stainless steel 316 L
- pressure connection:
- Stainless steel 316 L
- diaphragm:
- ceramic (Al2O3 96 %)
- Seal:
- FKM (Viton)
- Supply voltage
- DC 9 − 32 V
- Output signal
- 2-wire, 4–20 mA
- Load
- Rmax = [(UB – UBmin)/0.02 A] Ω
- Current input
- < 21 mA
- electrical protection
- short circuit proof and protected against reverse polarity
- Electrical connection
- Connector and junction box as per ISO 4400 (DIN 43650-A)
- Degree of protection
- IP 65 (EN 60529)
- CE conformity
- EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU
Pressure Equipment Directive 2014/68/EU
Druckmessumformer DMU 07/DMU 07 FG/DMU 08/DMU 08 T/DMU 09/ DMU 10 D/ DMU 11 D
Domestic Technology
PDF
Druckmessumformer DMU 03…Ex, DMU 04…Ex, DMU 05…Ex, DMU 07…Ex
PDF
Druckmessumformer DMU 01, DMU 01 K, DMU 03, DMU 03 HD, DMU 04, DMU 05P, DMU 07, DMU 07 FG
PDF
elektronische Druckmesstechnik - Druckmessumformer Serie DMU
PDF