Skip to main content

KP80 D311

Kapselfeder-Standardmanometer Typ D3

housing ⌀ (nominal size)80 mm
ConnectionG½B
alignmentcentre back
accuracy class1,6
standardEN 837-3

  • with zero correction
  • ideal for low pressure ranges
  • GOSSTANDART-certified

For gaseous, dry media which do not attack copper alloys.
! For measuring gas or vapour, observe the table "Selection Criteria as per EN 837-2" (see appendix)!

RangeMounting typeTypePart number
-25/0 mbardirectKP80 D31135054311
-40/0 mbardirectKP80 D31135055311
-60/0 mbardirectKP80 D31135056311
-100/0 mbardirectKP80 D31135057311
-160/0 mbardirectKP80 D31135058311
-250/0 mbardirectKP80 D31135059311
-400/0 mbardirectKP80 D31135060311
-600/0 mbardirectKP80 D31135061311
-1 000/0 mbardirectKP80 D31135062311
0/25 mbardirectKP80 D31135066311
0/40 mbardirectKP80 D31135067311
0/60 mbardirectKP80 D31135068311
0/100 mbardirectKP80 D31135069311
0/160 mbardirectKP80 D31135070311
0/250 mbardirectKP80 D31135071311
0/400 mbardirectKP80 D31135072311
0/600 mbardirectKP80 D31135073311
0/1 000 mbardirectKP80 D31135074311
  • in-stock items
  • manufactured goods

Type
D3
Nominal size
80 - 80
accuracy class (EN 837-3/6)
1,6
ranges (EN 837-3/5)
see ordering table
application area
static load:
Full scale value
dynamic load:
0.9 x full scale value
overload safety:
1.3 x full scale value
Operating temperature range
Medium:
max. 60 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,6 %/10 K,
falling temperature approx. ± 0.6 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
NG 80: IP 33 (EN 60529)

Standard design

Connection
Brass, centre back
Measuring element
Capsule element, CuBe alloy
movement
Brass
Zero correction
from the front
Seal
NBR (Perbunan)
Dial
Aluminium, weiß
Scaling black
Pointer
Aluminium, schwarz
Housing
Edelstahl 304
window
Kunststoff, eingeclipst

Click the corresponding image for detail views, additional information and dimension tables.

854_017_0336-00.PDF

Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck

PDF

Options for capsule pressure gauges
Abb.
Bezeichnung
connection socket nickel-plated NG 80 | 38085
throttle screw stainless steel 316 Ti NG 80 hole 0.3 – 0.5 – 0.7 mm (please specify) | 38104
 back flange  stainless steel 304, vibratory-finished NG 80
back flange stainless steel 304, vibratory-finished NG 80 | 38049
Housing stainless steel 304 polished NG 80 | 37612
red mark on dial NG 80 | 38185
1 reference pointer, red NG 80 SD External adjustment with screwdriver | 38116
1 reference pointer, red NG 80 DK external rotary knob adjustment | 38189
oil and grease removed from wetted parts NG 80 label "Oil and grease free" | 37616
printing block creation per scale and colour NG 80 scale design as per EN 837-1, others on request | 38154
additional colour NG 80 | 38166