MD 56
Membrandruckmittler NEUMO BioControl®
- defined installation and press-fitting with metal stop
- medium cannot get behind the seal
- SIP/CIP enabled
Flange type diaphragm seal MD 56 for sterile process separation of pressure measuring and control units in pipes or tanks. For mounting to Bourdon tube pressure gauges, pressure transducers and pressure switches. For installation in sterile processes without dead spaces. Typical application areas:
Sterile applications in process engineering
Pharmaceutical industry
Biotechnology
Food and beverages industry
Beverage machines
Dairies
Breweries
All materials used are FDA-listed. Defined installation as per EHEDG hygienic design recommendations. The chemical seal and the measuring instrument are welded together, resulting in an inseparable single, shock- and vibration-resistant unit without external edges that might collect dirt. The chemical seals are available with nominal diameters 25, 50, 65, 80; due to their compact design, they are suitable for a wide range of applications.
- in-stock items
- manufactured goods
- Process connection
- Stainless steel 316 L
- NEUMO BioControl®
- D25
- diaphragm
- Stainless steel 316 L
- material (wetted parts)
- Stainless steel 316 L, EPDM
- USP CLASS VI classified, FDA-gelistet
- surface roughness Ra
- ≤ 0.8 µm
- Seal
- EPDM
- Instrument connection
- Welded connection
- pressure transmission liquid
- Paraffin oil (FM 09), FDA-listed
- pressure range
- see overview of versions
- Nominal pressure
- PN 16
- Can be mounted to
- Bourdon tube pressure gauges NG 50, 63, 80, 100, 160
- Druckmessumformer (DMU)
- Pressure switches (DS)