Pressure transducers DMU 13 with local display

 SAR 61870 61880 61890 61900 61910 61920 61930 61940 61950 object_image_64261imagemain_en
 BEF 61870 61880 61890 61900 61910 61920 61930 61940 61950
Data sheet Pressure transducers DMU 13 with local display
AFRISO Data sheet Pressure transducers DMU 13 with local display

Versions

Type Connection Measuring range Part no. Remember
DMU 13 G½B EN 837-1/7.3 0/1 bar 31077
DMU 13 G½B EN 837-1/7.3 0/1.6 bar 31078
DMU 13 G½B EN 837-1/7.3 0/2.5 bar 31079
DMU 13 G½B EN 837-1/7.3 0/4 bar 31080
DMU 13 G½B EN 837-1/7.3 0/6 bar 31081
DMU 13 G½B EN 837-1/7.3 0/10 bar 31082
DMU 13 G½B EN 837-1/7.3 0/16 bar 31083
DMU 13 G½B EN 837-1/7.3 0/25 bar 31084
DMU 13 G½B EN 837-1/7.3 0/40 bar 31085

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Pressure transducers DMU 13 with local display Data sheet PDF
AFRISO Data sheet Pressure transducers DMU 13 with local display
Electronic pressure measurement - pressure transducers DMU series Product range industrial technology PDF
AFRISO Electronic pressure measurement - pressure transducers DMU series
Enquiry pressure transducers DMU Checklists PDF
AFRISO Enquiry pressure transducers DMU
The DMU 13 pressure transducers consist of a mechanical Bourdon tube measuring element and a piezo-resistive stainless steel measuring cell. The Bourdon tube measuring element is used to provide an easy-to-read analogue local display. The display is power-independent. Due to the integrated pressure transducer, high-precision measurement in parallel is possible. A standardised current output is available for signal transmission and recording of measured data. The robust stainless steel housing has a solid baffle wall and blow out (safety housing).
Nominal size
100
Accuracy class (EN 837-1/6)
1,0
Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
< ± 0.5 % FSO
Long-term stability
≤ ± 0.2 % FSO/Jahr
Measuring range
See ordering table
Application area
Static load:
Full scale value
Dynamic load:
0.9 x full scale value
Short-term load:
1.3 x full scale value
Operating temperature range
Medium:
-20/+100 °C
Ambient:
-20/+60 °C
Storage:
-40/+70 °C
Temperature error band
≤ 1 % FSO/10 K In compensated range 0/70 °C
Housing
With solid baffle wall and blow-out (S3)
Window
Laminated safety glass
Process connection
G½B EN 837-1/7.3, bottom
Material
Housing:
Stainless steel 304
Pressure connection:
Stainless steel 316 L
Diaphragm:
Stainless steel 316 L
Seal:
FKM (Viton)
Wetted parts
Stainless steel 316 Ti/316 L
Pressure transmission liquid
Silicone oil
Supply voltage
DC 12 – 36 V
Output signal
2-wire, 4–20 mA
Load
R<sub>Max</sub> = [(UB – UB<sub>Min</sub>)/0.02 A] Ω
Current input
< 25 mA
Electrical connection
Junction box
Degree of protection
IP 54 (EN 60529)

Options

  • Housing filling (paraffin oil)
  • Electrical contacts
  • Other connectors
  • Other process connections
  • Fitting of chemical seal
DMU 13 - bottom connection
DMU 13 - bottom connection
AFRISO
Dimensions (in mm)