Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. We strive to improve the environment, to make processes which work with greater environmental compatibility and to avoid putting a strain on the environment. We offer you a multitude of innovative solutions, new products and smart concepts. More Informations Industries & Topics Industries & Topics Overview Fuel oil components Fuel oil components Overview Fast and clean oil filter change Avoiding fungal attacks in biofuel More performance with the sintered plastic sieve AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview AFRISOhome App Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home Craft 4.0 Craft 4.0 Overview OEM-Manifold systems Hydraulic Balancing Hydraulic Balancing Overview VarioQ Vario-DP Tank conversion Hygienic processes AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search Domestic technology Pressure measuring instruments for domestic technology RF100I D401 Images 5 RF100I D401 Rohrfeder-Industriemanometer Typ D4 Variants Documents Info housing ⌀ (nominal size)100 mmConnectionG½Balignmentbottomaccuracy class1,0standardEN 837-1 Benefits for machine and plant engineeringrobust, stainless steel housing with bayonet bezelcan be equipped with electrical contactDNV-GL- and GOSSTANDART-certified Application For gaseous and liquid media which are not highly viscous, do not crystallise and do not attack copper alloys. For high accuracy and rough application conditions.! For measuring gas or vapour, observe the table "Selection Criteria as per EN 837-2" (see appendix)! Variants Technical data Technical drawings Downloads Variants RangeMounting typeTypePart number-1/0 bardirectRF100I D40185301401-1/0.6 bardirectRF100I D40185302401-1/+1.5 bardirectRF100I D40185303401-1/+3 bardirectRF100I D40185304401-1/+5 bardirectRF100I D40185305401-1/+9 bardirectRF100I D40185306401-1/+15 bardirectRF100I D401853074010/0.6 bardirectRF100I D401853094010/1 bardirectRF100I D401853104010/1.6 bardirectRF100I D401853114010/2.5 bardirectRF100I D401853124010/4 bardirectRF100I D401853134010/6 bardirectRF100I D401853144010/10 bardirectRF100I D401853154010/16 bardirectRF100I D401853164010/25 bardirectRF100I D401853174010/40 bardirectRF100I D401853184010/60 bardirectRF100I D401853194010/100 bardirectRF100I D401853204010/160 bardirectRF100I D401853214010/250 bardirectRF100I D401853224010/400 bardirectRF100I D401853234010/600 bardirectRF100I D401853244010/1 000 bardirectRF100I D40185325401 in-stock items manufactured goods Technical data TypeD4Nominal size100 - 100accuracy class (EN 837-1/6)1,0ranges (EN 837-1/5)see ordering tableapplication areastatic load≤ 600 bar: Full scale value> 600 bar: ¾ x full scale valuedynamic load≤ 600 bar: 0.9 x full scale value> 600 bar: ⅔ x full scale valueshort-term≤ 600 bar: 1.3 x full scale value> 600 bar: Full scale valueOperating temperature rangeMedium: max. 60 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,4 %/10 K,falling temperature approx. ± 0.4 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 54 (EN 60529) Standard design ConnectionBrass, bottomMeasuring elementBourdon tube≤ 60 bar: "C" type tube, Copper alloy> 60 bar: helical tube, stainless steel 316 Ti/316 LmovementBrassDialAluminium, weißScaling blackPointerAluminium, schwarzHousingEdelstahl 304, with blow-outbayonet bezelEdelstahl 304windowInstrumentenglas Technical drawings Click the corresponding image for detail views, additional information and dimension tables. Bottom connection Dimensions (mm) NG a b ∅c c1 c2 G h SW 100 15,6 49 6 3 20 G½B 86 22 160 17,5 50 6 3 20 G½B 116 22 250 16 57 6 3 20 G½B 165 22 Downloads Rohrfeder-Manometer Domestic Technology PDF English German AFRISO_EU-KONFORMITAETSERKLAERUNG_DRUCKGERAETE_DE.PDF Industrial technology PDF Download Montage Manometer Manuals Industrial technology PDF Download Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck Manuals Industrial technology PDF Ukrainian German German RF100I_D401_853XX401.STP STEP 3D Modell Domestic Technology STP Download Related products
AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
Images 5 RF100I D401 Rohrfeder-Industriemanometer Typ D4 Variants Documents Info housing ⌀ (nominal size)100 mmConnectionG½Balignmentbottomaccuracy class1,0standardEN 837-1 Benefits for machine and plant engineeringrobust, stainless steel housing with bayonet bezelcan be equipped with electrical contactDNV-GL- and GOSSTANDART-certified Application For gaseous and liquid media which are not highly viscous, do not crystallise and do not attack copper alloys. For high accuracy and rough application conditions.! For measuring gas or vapour, observe the table "Selection Criteria as per EN 837-2" (see appendix)! Variants Technical data Technical drawings Downloads Variants RangeMounting typeTypePart number-1/0 bardirectRF100I D40185301401-1/0.6 bardirectRF100I D40185302401-1/+1.5 bardirectRF100I D40185303401-1/+3 bardirectRF100I D40185304401-1/+5 bardirectRF100I D40185305401-1/+9 bardirectRF100I D40185306401-1/+15 bardirectRF100I D401853074010/0.6 bardirectRF100I D401853094010/1 bardirectRF100I D401853104010/1.6 bardirectRF100I D401853114010/2.5 bardirectRF100I D401853124010/4 bardirectRF100I D401853134010/6 bardirectRF100I D401853144010/10 bardirectRF100I D401853154010/16 bardirectRF100I D401853164010/25 bardirectRF100I D401853174010/40 bardirectRF100I D401853184010/60 bardirectRF100I D401853194010/100 bardirectRF100I D401853204010/160 bardirectRF100I D401853214010/250 bardirectRF100I D401853224010/400 bardirectRF100I D401853234010/600 bardirectRF100I D401853244010/1 000 bardirectRF100I D40185325401 in-stock items manufactured goods Technical data TypeD4Nominal size100 - 100accuracy class (EN 837-1/6)1,0ranges (EN 837-1/5)see ordering tableapplication areastatic load≤ 600 bar: Full scale value> 600 bar: ¾ x full scale valuedynamic load≤ 600 bar: 0.9 x full scale value> 600 bar: ⅔ x full scale valueshort-term≤ 600 bar: 1.3 x full scale value> 600 bar: Full scale valueOperating temperature rangeMedium: max. 60 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,4 %/10 K,falling temperature approx. ± 0.4 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 54 (EN 60529) Standard design ConnectionBrass, bottomMeasuring elementBourdon tube≤ 60 bar: "C" type tube, Copper alloy> 60 bar: helical tube, stainless steel 316 Ti/316 LmovementBrassDialAluminium, weißScaling blackPointerAluminium, schwarzHousingEdelstahl 304, with blow-outbayonet bezelEdelstahl 304windowInstrumentenglas Technical drawings Click the corresponding image for detail views, additional information and dimension tables. Bottom connection Dimensions (mm) NG a b ∅c c1 c2 G h SW 100 15,6 49 6 3 20 G½B 86 22 160 17,5 50 6 3 20 G½B 116 22 250 16 57 6 3 20 G½B 165 22 Downloads Rohrfeder-Manometer Domestic Technology PDF English German AFRISO_EU-KONFORMITAETSERKLAERUNG_DRUCKGERAETE_DE.PDF Industrial technology PDF Download Montage Manometer Manuals Industrial technology PDF Download Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck Manuals Industrial technology PDF Ukrainian German German RF100I_D401_853XX401.STP STEP 3D Modell Domestic Technology STP Download
Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck Manuals Industrial technology PDF Ukrainian German German