Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. We strive to improve the environment, to make processes which work with greater environmental compatibility and to avoid putting a strain on the environment. We offer you a multitude of innovative solutions, new products and smart concepts. More Informations Industries & Topics Industries & Topics Overview Fuel oil components Fuel oil components Overview Fast and clean oil filter change Avoiding fungal attacks in biofuel More performance with the sintered plastic sieve AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview AFRISOhome App Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home Craft 4.0 Craft 4.0 Overview OEM-Manifold systems Hydraulic Balancing Hydraulic Balancing Overview VarioQ Vario-DP Tank conversion Hygienic processes AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search Domestic technology Pressure measuring instruments for domestic technology RF100I D411 Images 5 RF100I D411 Rohrfeder-Industriemanometer Typ D4 Variants Documents Info housing ⌀ (nominal size)100 mmConnectionG½Balignmentbottom backaccuracy class1,0standardEN 837-1 Benefits for machine and plant engineeringrobust, stainless steel housing with bayonet bezelcan be equipped with electrical contactDNV-GL- and GOSSTANDART-certified Application For gaseous and liquid media which are not highly viscous, do not crystallise and do not attack copper alloys. For high accuracy and rough application conditions.! For measuring gas or vapour, observe the table "Selection Criteria as per EN 837-2" (see appendix)! Variants Technical data Technical drawings Downloads Variants RangeMounting typeTypePart number-1/0 bardirectRF100I D41185301411-1/0.6 bardirectRF100I D41185302411-1/+1.5 bardirectRF100I D41185303411-1/+3 bardirectRF100I D41185304411-1/+5 bardirectRF100I D41185305411-1/+9 bardirectRF100I D41185306411-1/+15 bardirectRF100I D411853074110/0.6 bardirectRF100I D411853094110/1 bardirectRF100I D411853104110/1.6 bardirectRF100I D411853114110/2.5 bardirectRF100I D411853124110/4 bardirectRF100I D411853134110/6 bardirectRF100I D411853144110/10 bardirectRF100I D411853154110/16 bardirectRF100I D411853164110/25 bardirectRF100I D411853174110/40 bardirectRF100I D411853184110/60 bardirectRF100I D411853194110/100 bardirectRF100I D411853204110/160 bardirectRF100I D411853214110/250 bardirectRF100I D411853224110/400 bardirectRF100I D411853234110/600 bardirectRF100I D411853244110/1 000 bardirectRF100I D41185325411 in-stock items manufactured goods Technical data TypeD4Nominal size100 - 100accuracy class (EN 837-1/6)1,0ranges (EN 837-1/5)see ordering tableapplication areastatic load≤ 600 bar: Full scale value> 600 bar: ¾ x full scale valuedynamic load≤ 600 bar: 0.9 x full scale value> 600 bar: ⅔ x full scale valueshort-term≤ 600 bar: 1.3 x full scale value> 600 bar: Full scale valueOperating temperature rangeMedium: max. 60 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,4 %/10 K,falling temperature approx. ± 0.4 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 54 (EN 60529) Standard design ConnectionBrass, bottom backMeasuring elementBourdon tube≤ 60 bar: "C" type tube, Copper alloy> 60 bar: helical tube, stainless steel 316 Ti/316 LmovementBrassDialAluminium, weißScaling blackPointerAluminium, schwarzHousingEdelstahl 304, with blow-outbayonet bezelEdelstahl 304windowInstrumentenglas Technical drawings Click the corresponding image for detail views, additional information and dimension tables. bottom back connection Dimensions (mm) NG b2∅c c1 c2 e G g SW 100 49 6 3 20 26,5 G½B 81 22 160 50 6 3 20 26,5 G½B 82 22 250 - 6 3 20 - G½B - 22 Downloads Rohrfeder-Manometer Domestic Technology PDF English German AFRISO_EU-KONFORMITAETSERKLAERUNG_DRUCKGERAETE_DE.PDF Industrial technology PDF Download Montage Manometer Manuals Industrial technology PDF Download Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck Manuals Industrial technology PDF Ukrainian German German RF100I_D411_853XX411.STP STEP 3D Modell Domestic Technology STP Download Related products
AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
Images 5 RF100I D411 Rohrfeder-Industriemanometer Typ D4 Variants Documents Info housing ⌀ (nominal size)100 mmConnectionG½Balignmentbottom backaccuracy class1,0standardEN 837-1 Benefits for machine and plant engineeringrobust, stainless steel housing with bayonet bezelcan be equipped with electrical contactDNV-GL- and GOSSTANDART-certified Application For gaseous and liquid media which are not highly viscous, do not crystallise and do not attack copper alloys. For high accuracy and rough application conditions.! For measuring gas or vapour, observe the table "Selection Criteria as per EN 837-2" (see appendix)! Variants Technical data Technical drawings Downloads Variants RangeMounting typeTypePart number-1/0 bardirectRF100I D41185301411-1/0.6 bardirectRF100I D41185302411-1/+1.5 bardirectRF100I D41185303411-1/+3 bardirectRF100I D41185304411-1/+5 bardirectRF100I D41185305411-1/+9 bardirectRF100I D41185306411-1/+15 bardirectRF100I D411853074110/0.6 bardirectRF100I D411853094110/1 bardirectRF100I D411853104110/1.6 bardirectRF100I D411853114110/2.5 bardirectRF100I D411853124110/4 bardirectRF100I D411853134110/6 bardirectRF100I D411853144110/10 bardirectRF100I D411853154110/16 bardirectRF100I D411853164110/25 bardirectRF100I D411853174110/40 bardirectRF100I D411853184110/60 bardirectRF100I D411853194110/100 bardirectRF100I D411853204110/160 bardirectRF100I D411853214110/250 bardirectRF100I D411853224110/400 bardirectRF100I D411853234110/600 bardirectRF100I D411853244110/1 000 bardirectRF100I D41185325411 in-stock items manufactured goods Technical data TypeD4Nominal size100 - 100accuracy class (EN 837-1/6)1,0ranges (EN 837-1/5)see ordering tableapplication areastatic load≤ 600 bar: Full scale value> 600 bar: ¾ x full scale valuedynamic load≤ 600 bar: 0.9 x full scale value> 600 bar: ⅔ x full scale valueshort-term≤ 600 bar: 1.3 x full scale value> 600 bar: Full scale valueOperating temperature rangeMedium: max. 60 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,4 %/10 K,falling temperature approx. ± 0.4 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 54 (EN 60529) Standard design ConnectionBrass, bottom backMeasuring elementBourdon tube≤ 60 bar: "C" type tube, Copper alloy> 60 bar: helical tube, stainless steel 316 Ti/316 LmovementBrassDialAluminium, weißScaling blackPointerAluminium, schwarzHousingEdelstahl 304, with blow-outbayonet bezelEdelstahl 304windowInstrumentenglas Technical drawings Click the corresponding image for detail views, additional information and dimension tables. bottom back connection Dimensions (mm) NG b2∅c c1 c2 e G g SW 100 49 6 3 20 26,5 G½B 81 22 160 50 6 3 20 26,5 G½B 82 22 250 - 6 3 20 - G½B - 22 Downloads Rohrfeder-Manometer Domestic Technology PDF English German AFRISO_EU-KONFORMITAETSERKLAERUNG_DRUCKGERAETE_DE.PDF Industrial technology PDF Download Montage Manometer Manuals Industrial technology PDF Download Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck Manuals Industrial technology PDF Ukrainian German German RF100I_D411_853XX411.STP STEP 3D Modell Domestic Technology STP Download
Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck Manuals Industrial technology PDF Ukrainian German German