Measuring range-1/+5 bar
ConnectionG½B
ConnectionDIN 3852 type E
Electrical connectionConnector and junction box as per ISO 4400 (DIN 43650-A, EN 175301-803)
Part no.31622

  • proven ceramic technology
  • no mechanical ageing of the measuring cell
  • no transmission liquid
  • Versions for relative pressure and absolute pressure
  • small temperature error

For electronic pressure measurement in industrial applications (such as hydraulic and pneumatic applications as well as mechanical and plant engineering).

Pressure transducers convert physical pressure into an electrical signal proportional to the pressure. DMU 01 is equipped with a piezo-resistive thick-film ceramic measuring cell.

Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
< ± 0.5 % FSO
Measuring range
see ordering table
Overpressure safety
< 250 bar: at least 2 x FS
Burst pressure
< 400 bar: at least 3 x FS
Operating temperature range
Medium:
-25/+125 °C
Ambient:
-25/+85 °C
Storage:
-40/+85 °C
Temperature error band
≤ ± 0.3 % FSO/10 K ≤ ± In compensated range -25/+85 °C
dynamic characteristics
Response time:
≤ 10 ms
Process connection
G½B DIN 3852 type E with protruding diaphragm
material
Housing:
Stainless steel 304
pressure connection:
Stainless steel 304
diaphragm:
ceramic (Al2O3 96 %)
Seal:
FKM (Viton)
Supply voltage
DC 8 − 32 V
Output signal
2-wire, 4–20 mA
Load
Rmax = [(UB – UBmin)/0.02 A] Ω
Current input
< 25 mA
electrical protection
short circuit proof and protected against reverse polarity
Electrical connection
Connector and junction box as per ISO 4400 (DIN 43650-A, EN 175301-803)
Degree of protection
IP 65 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU
Pressure Equipment Directive 2014/68/EU