Skip to main content
Back

HydroFox® DMU 08 T | 31562T0070

Druckmessumformer Pegelsonde

manufactured goods

Measuring range0/1.6 bar
Part no.31562T0070

  • with integrated temperature measurement
  • compact and sturdy stainless steel design
  • integrated overvoltage protection
  • special calibration for all standard pressure units possible

For electronic, continuous level measurement, e.g. in wells, drilling holes, water, containers or in waste water systems. Suitable for groundwater, waste water (with optional FEP cable), diesel fuel and fuel oil.

Pressure transducers HydroFox® DMU 08 convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 08 uses a piezo-resistive silicon measuring cell.

Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
> 0/400 mbar < ± 0.35 % FSO
Measuring range
see ordering table
Operating temperature range
Medium:
-10/+70 °C
Ambient:
-10/+70 °C
Storage:
-25/+70 °C
Temperature error band
> 400 mbar: ≤ ± 0.75 % FSO ≤ ± In compensated range 0/70 °C
dynamic characteristics
Response time:
≤ 10 ms
Probe
L x ⌀:
129 x 26.5 mm
material
Housing:
Stainless steel 316 L
diaphragm:
Stainless steel 316 L
seals:
FKM (Viton)
cable:
PUR
pressure transmission liquid
Silicone oil
Supply voltage
pressure:
DC 12 − 30 V
temperature:
DC 10 − 30 V
Output signal
4–20 mA, 2-wire
Load
Rmax = [(UB – UBmin)/0.02 A] Ω
Current input
< 25 mA
electrical protection
short circuit proof and protected against reverse polarity
Electrical connection
PUR cable with integrated breather tube for reference to the ambient atmospheric pressure
Cable length:
5 m
Degree of protection:
IP 68 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU
Pressure Equipment Directive 2014/68/EU

900_100_0832.PDF

Tauchsonde DMU 08, DMU 08 T, DMU 09

PDF