Skip to main content

KP100 D411

Kapselfeder-Standardmanometer Typ D4

housing ⌀ (nominal size)100 mm
ConnectionG½B
alignmentcentre back
accuracy class1,6
standardEN 837-3

  • with zero correction
  • optional overpressure and/or underpressure safety 10 x FSD
  • extremely low measuring ranges from 0/6 mbar
  • GOSSTANDART-certified

For gaseous, dry media which do not attack copper alloys.
! For measuring gas or vapour, observe the table "Selection Criteria as per EN 837-2" (see appendix)!

RangeMounting typeTypePart number
-25/0 mbardirectKP100 D41135104411
-40/0 mbardirectKP100 D41135105411
-60/0 mbardirectKP100 D41135106411
-100/0 mbardirectKP100 D41135107411
-160/0 mbardirectKP100 D41135108411
-250/0 mbardirectKP100 D41135109411
-400/0 mbardirectKP100 D41135110411
-600/0 mbardirectKP100 D41135111411
-1 000/0 mbardirectKP100 D41135112411
0/25 mbardirectKP100 D41135116411
0/40 mbardirectKP100 D41135117411
0/60 mbardirectKP100 D41135118411
0/100 mbardirectKP100 D41135119411
0/160 mbardirectKP100 D41135120411
0/250 mbardirectKP100 D41135121411
0/400 mbardirectKP100 D41135122411
0/600 mbardirectKP100 D41135123411
0/1 000 mbardirectKP100 D41135124411
  • in-stock items
  • manufactured goods

Type
D4
Nominal size
100 - 100
accuracy class (EN 837-3/6)
1,6
ranges (EN 837-3/5)
see ordering table
application area
static load:
Full scale value
dynamic load:
0.9 x full scale value
overload safety:
1.3 x full scale value
Operating temperature range
Medium:
max. 60 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,6 %/10 K,
falling temperature approx. ± 0.6 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
NG 100: IP 54 (EN 60529)

Standard design

Connection
Brass, centre back
Measuring element
Capsule element, CuBe alloy
movement
Brass
Zero correction
from the front
Seal
NBR (Perbunan)
Dial
Aluminium, weiß
Scaling black
Pointer
Aluminium, schwarz
Housing
Edelstahl 304
bayonet bezel
Edelstahl 304
window
D411: Instrumentenglas

Click the corresponding image for detail views, additional information and dimension tables.

854_017_0336-00.PDF

Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck

PDF

Options for capsule pressure gauges
Abb.
Bezeichnung
accuracy class 1.0 NG 100 | 38180
connection socket nickel-plated NG 100 | 38086
throttle screw brass NG 100 hole 0.3 – 0.5 – 0.7 mm (please specify) | 38099
3-hole fixing, panel mounting bezel stainless steel 304, polished NG 100 | 37609
 back flange  stainless steel 304, vibratory-finished NG 100
back flange stainless steel 304, vibratory-finished NG 100 | 38050
bayonet bezel stainless steel 304, polished NG 100 | 38053
Housing stainless steel 304, polished NG 100 | 37613
red mark on dial NG 100 | 38186
1 reference pointer, red NG 100 SD External adjustment with screwdriver | 38117
1 reference pointer, red NG 100 DK external rotary knob adjustment | 38190
laminated safety glass window NG 100 | 38074
higher degree of protection IP 54 NG 100 | 38160
printing block creation per scale and colour NG 100 scale design as per EN 837-1, others on request | 38155
additional colour NG 100 | 38167
 3-hole fixing, panel mounting bezel (bayonet type)  stainless steel 304, polished NG 100 for factory-mounting
3-hole fixing, panel mounting bezel (bayonet type) stainless steel 304, polished NG 100 for factory-mounting | 38056