Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview Fuel oil components Fuel oil components Overview Fast and clean oil filter change Avoiding fungal attacks in biofuel More performance with the sintered plastic sieve AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway Produkte Sicherheit Komfort Raumklima AFRISOhome App Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home Craft 4.0 Craft 4.0 Overview EUROLYZER® CAPBs®-Sets CAPBs®-Sets Overview App OEM-Manifold systems Hydraulic Balancing Hydraulic Balancing Overview Vario-DP Tank conversion Hygienic processes AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview GET Nord 2026, Hamburg Search Industrial technology Mechanical pressure measuring instruments PF160Gly D801 Images 1 PF160Gly D801 Plattenfeder-Standardmanometer Typ D8 mit Glyzerinfüllung Variants Documents Info housing ⌀ (nominal size)160 mmaccuracy class1,6standardEN 837-3 Benefits Overpressure safety 10 barsmallest rangesrobust and compact designwetted area without seals due to weldingEx version (optional) Variants Technical data Technical drawings Downloads Variants RangeMounting typeTypePart number0/0.4 bardirectPF160Gly D801859598010/0.6 bardirectPF160Gly D801859608010/1 bardirectPF160Gly D801859618010/1.6 bardirectPF160Gly D801859628010/2.5 bardirectPF160Gly D801859638010/4 bardirectPF160Gly D801859648010/6 bardirectPF160Gly D801859658010/10 bardirectPF160Gly D801859668010/16 bardirectPF160Gly D801859678010/25 bardirectPF160Gly D80185968801 in-stock items manufactured goods Technical data TypeD8Nominal size160 - 160accuracy class (EN 837-3/6)1,6ranges (EN 837-3/5)see ordering tableapplication areastatic load: Full scale valuedynamic load: 0.9 x full scale valueOverpressure safety≤ 0.4 bar: at least 1.3 x FS≥ 0.6 bar: at least 5 x FS≥ 10 bar: max. 40 barOperating temperature rangeMedium: max. 100 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,8 %/10 K,falling temperature approx. ± 0.8 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 54 (EN 60529) Standard design ConnectionSteel, bottomG½B, SW22 (EN 837-3/7.3)lower measuring flangeSteelupper measuring flangeStainless steel 304Measuring elementdiaphragmmeasuring flange ⌀ 100, ≤ 0/1.6 bar: Durathermmeasuring flange ⌀ 100, ≥ 0/2.5 bar: steel, galvanisedSealNBR (Perbunan)movementBrassDialAluminium, weißScaling blackPointerAluminium, schwarzHousingEdelstahl 304, with blow-outbayonet bezelEdelstahl 304windowInstrumentenglasfilling liquidGlycerine Technical drawings Click the corresponding image for detail views, additional information and dimension tables. bottom connection, measuring flange ⌀ 160 Dimensions (mm) NG a b∅c c1 c2 D1 G h SW 160 20 55 6 3 20 160 G½B 156 22 Downloads EU-Konformitätserklärung Druckgeräte Declarations of Conformity PDF Download Montage Manometer operating instructions Industrial technology PDF Download Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck operating instructions Industrial technology PDF Ukrainian German German Related products
AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview GET Nord 2026, Hamburg Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview GET Nord 2026, Hamburg Search
Images 1 PF160Gly D801 Plattenfeder-Standardmanometer Typ D8 mit Glyzerinfüllung Variants Documents Info housing ⌀ (nominal size)160 mmaccuracy class1,6standardEN 837-3 Benefits Overpressure safety 10 barsmallest rangesrobust and compact designwetted area without seals due to weldingEx version (optional) Variants Technical data Technical drawings Downloads Variants RangeMounting typeTypePart number0/0.4 bardirectPF160Gly D801859598010/0.6 bardirectPF160Gly D801859608010/1 bardirectPF160Gly D801859618010/1.6 bardirectPF160Gly D801859628010/2.5 bardirectPF160Gly D801859638010/4 bardirectPF160Gly D801859648010/6 bardirectPF160Gly D801859658010/10 bardirectPF160Gly D801859668010/16 bardirectPF160Gly D801859678010/25 bardirectPF160Gly D80185968801 in-stock items manufactured goods Technical data TypeD8Nominal size160 - 160accuracy class (EN 837-3/6)1,6ranges (EN 837-3/5)see ordering tableapplication areastatic load: Full scale valuedynamic load: 0.9 x full scale valueOverpressure safety≤ 0.4 bar: at least 1.3 x FS≥ 0.6 bar: at least 5 x FS≥ 10 bar: max. 40 barOperating temperature rangeMedium: max. 100 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,8 %/10 K,falling temperature approx. ± 0.8 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 54 (EN 60529) Standard design ConnectionSteel, bottomG½B, SW22 (EN 837-3/7.3)lower measuring flangeSteelupper measuring flangeStainless steel 304Measuring elementdiaphragmmeasuring flange ⌀ 100, ≤ 0/1.6 bar: Durathermmeasuring flange ⌀ 100, ≥ 0/2.5 bar: steel, galvanisedSealNBR (Perbunan)movementBrassDialAluminium, weißScaling blackPointerAluminium, schwarzHousingEdelstahl 304, with blow-outbayonet bezelEdelstahl 304windowInstrumentenglasfilling liquidGlycerine Technical drawings Click the corresponding image for detail views, additional information and dimension tables. bottom connection, measuring flange ⌀ 160 Dimensions (mm) NG a b∅c c1 c2 D1 G h SW 160 20 55 6 3 20 160 G½B 156 22 Downloads EU-Konformitätserklärung Druckgeräte Declarations of Conformity PDF Download Montage Manometer operating instructions Industrial technology PDF Download Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck operating instructions Industrial technology PDF Ukrainian German German
Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck operating instructions Industrial technology PDF Ukrainian German German