RF100Ch IK2 D402

Rohrfeder-Chemiemanometer mit Grenzsignalgeber Typ D4

housing ⌀ (nominal size)100 mm
ConnectionG½B
alignmentbottom
accuracy class1,0

  • measuring system fully welded to housing
  • robust mechatronical pressure gauge
  • Up to four switching contacts
  • tightness-tested with helium
  • GOSSTANDART-certified

For corrosive gaseous and liquid media which are not highly viscous and do not crystallise; suitable for corrosive environments.

RangeMounting typeTypePart number
-1/0 bardirectRF100Ch IK2 D40287751402
-1/0.6 bardirectRF100Ch IK2 D40287752402
-1/+1.5 bardirectRF100Ch IK2 D40287753402
-1/+3 bardirectRF100Ch IK2 D40287754402
-1/+5 bardirectRF100Ch IK2 D40287755402
-1/+9 bardirectRF100Ch IK2 D40287756402
-1/+15 bardirectRF100Ch IK2 D40287757402
0/0.6 bardirectRF100Ch IK2 D40287759402
0/1 bardirectRF100Ch IK2 D40287760402
0/1.6 bardirectRF100Ch IK2 D40287761402
0/2.5 bardirectRF100Ch IK2 D40287762402
0/4 bardirectRF100Ch IK2 D40287763402
0/6 bardirectRF100Ch IK2 D40287764402
0/10 bardirectRF100Ch IK2 D40287765402
0/16 bardirectRF100Ch IK2 D40287766402
0/25 bardirectRF100Ch IK2 D40287767402
0/40 bardirectRF100Ch IK2 D40287768402
0/60 bardirectRF100Ch IK2 D40287769402
0/100 bardirectRF100Ch IK2 D40287770402
0/160 bardirectRF100Ch IK2 D40287771402
0/250 bardirectRF100Ch IK2 D40287772402
0/400 bardirectRF100Ch IK2 D40287773402
0/600 bardirectRF100Ch IK2 D40287774402
0/1 000 bardirectRF100Ch IK2 D40287775402
  • in-stock items
  • manufactured goods

Type
D4
Nominal size
100 - 100
accuracy class (EN 837-1/6)
1,0
ranges (EN 837-1/5)
see ordering table
application area
static load
≤ 600 bar:
Full scale value
> 600 bar:
¾ x full scale value
dynamic load
≤ 600 bar:
0.9 x full scale value
> 600 bar:
⅔ x full scale value
short-term
≤ 600 bar:
1.3 x full scale value
> 600 bar:
Full scale value
contact types
inductive contact (IK)
minimum range
Contact
IK dual: 1 bar
Operating temperature range
Medium:
max. 150 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,4 %/10 K,
falling temperature approx. ± 0.4 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
IP 54 (EN 60529)

Standard design

Connection
stainless steel 316 Ti/316 L, bottom
G½B, SW22 (EN 837-1/7.3)
Electrical connection
Junction box
Measuring element
Bourdon tube, stainless steel 316 Ti/316 L
≤ 60 bar:
"C" type tube
> 60 bar:
helical tube
movement
Stainless steel
Dial
Aluminium, weiß
Scaling black
Pointer
Aluminium, schwarz
Housing
Edelstahl 304, with blow-out
bayonet bezel
Edelstahl 304
window
Kunststoff (Makrolon), with contact adjustment lock
Inductive contact (IK)
Supply voltage
DC 5 − 25 V
Current input
≥ 2.1 mA
Switching accuracy
approx. 0.5 % of full scale value
Operating temperature range
-20/+70 °C or corresponding to the respective measuring instruments
Adjustment range
5–95 % measuring range of gauge
Options
  • contact systems with safety integrity level SIL 2
Magnetic spring contact (MK)

Click the corresponding image for detail views, additional information and dimension tables.