Skip to main content

RF100I IK1 D401

Rohrfeder-Industriemanometer mit Grenzsignalgeber Typ D4

housing ⌀ (nominal size)100 mm
ConnectionG½B
alignmentbottom
accuracy class1,0

  • robust stainless steel housing
  • excellent readability
  • Up to four switching contacts
  • available with MK, EK, IK

For gaseous and liquid media which are not highly viscous, do not crystallise and do not attack copper alloys.

RangeMounting typeTypePart number
-1/0 bardirectRF100I IK1 D40187701401
-1/0.6 bardirectRF100I IK1 D40187702401
-1/+1.5 bardirectRF100I IK1 D40187703401
-1/+3 bardirectRF100I IK1 D40187704401
-1/+5 bardirectRF100I IK1 D40187705401
-1/+9 bardirectRF100I IK1 D40187706401
-1/+15 bardirectRF100I IK1 D40187707401
0/0.6 bardirectRF100I IK1 D40187709401
0/1 bardirectRF100I IK1 D40187710401
0/1.6 bardirectRF100I IK1 D40187711401
0/2.5 bardirectRF100I IK1 D40187712401
0/4 bardirectRF100I IK1 D40187713401
0/6 bardirectRF100I IK1 D40187714401
0/10 bardirectRF100I IK1 D40187715401
0/16 bardirectRF100I IK1 D40187716401
0/25 bardirectRF100I IK1 D40187717401
0/40 bardirectRF100I IK1 D40187718401
0/60 bardirectRF100I IK1 D40187719401
0/100 bardirectRF100I IK1 D40187720401
0/160 bardirectRF100I IK1 D40187721401
0/250 bardirectRF100I IK1 D40187722401
0/400 bardirectRF100I IK1 D40187723401
0/600 bardirectRF100I IK1 D40187724401
0/1 000 bardirectRF100I IK1 D40187725401
  • in-stock items
  • manufactured goods

Type
D4
Nominal size
100 - 100
accuracy class (EN 837-1/6)
1,0
ranges (EN 837-1/5)
see ordering table
application area
static load
≤ 600 bar:
Full scale value
> 600 bar:
¾ x full scale value
dynamic load
≤ 600 bar:
0.9 x full scale value
> 600 bar:
⅔ x full scale value
short-term
≤ 600 bar:
1.3 x full scale value
> 600 bar:
Full scale value
contact types
inductive contact (IK)
minimum range
Contact
IK Single: 1 bar
Operating temperature range
Medium:
max. 60 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,4 %/10 K,
falling temperature approx. ± 0.4 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
IP 54 (EN 60529)

Standard design

Connection
Brass, bottom
G½B, SW22 (EN 837-1/7.3)
Electrical connection
Cable gland M12 x 1.5
Kabel 1 m
Measuring element
Bourdon tube
≤ 60 bar:
"C" type tube, Copper alloy
> 60 bar:
helical tube, stainless steel 316 Ti/316 L
movement
Brass
Dial
Aluminium, weiß
Scaling black
Pointer
Aluminium, schwarz
Housing
Edelstahl 304, with blow-out
bayonet bezel
Edelstahl 304
window
Kunststoff (Makrolon), with contact adjustment lock
Inductive contact (IK)
Supply voltage
DC 5 − 25 V
Current input
≥ 2.1 mA
Switching accuracy
approx. 0.5 % of full scale value
Operating temperature range
-20/+70 °C or corresponding to the respective measuring instruments
Adjustment range
5–95 % measuring range of gauge
Options
  • contact systems with safety integrity level SIL 2
Magnetic spring contact (MK)

Click the corresponding image for detail views, additional information and dimension tables.

854_017_0336-00.PDF

Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck

PDF