Skip to main content

RF100ISR D171

Rohrfeder-Manometer mit Schraubringgehäuse Typ D1

housing ⌀ (nominal size)100 mm
ConnectionG½B
alignmentbottom
accuracy class1,0
standardEN 837-1

  • for machine and plant engineering
  • extremely robust plastic housing (PA 6.6 GB30)
  • laminated safety glass window
  • higher accuracy class optional

For gaseous and liquid media which are not highly viscous, do not crystallise and do not attack copper alloys. For high measuring accuracy.
! For measuring gas or vapour, observe the table "Selection Criteria as per EN 837-2"

RangeMounting typeTypePart number
-1/0 barback flangeRF100ISR D17185301171
-1/0.6 barback flangeRF100ISR D17185302171
-1/+1.5 barback flangeRF100ISR D17185303171
-1/+3 barback flangeRF100ISR D17185304171
-1/+5 barback flangeRF100ISR D17185305171
-1/+9 barback flangeRF100ISR D17185306171
-1/+15 barback flangeRF100ISR D17185307171
0/0.6 barback flangeRF100ISR D17185309171
0/1 barback flangeRF100ISR D17185310171
0/1.6 barback flangeRF100ISR D17185311171
0/2.5 barback flangeRF100ISR D17185312171
0/4 barback flangeRF100ISR D17185313171
0/6 barback flangeRF100ISR D17185314171
0/10 barback flangeRF100ISR D17185315171
0/16 barback flangeRF100ISR D17185316171
0/25 barback flangeRF100ISR D17185317171
0/40 barback flangeRF100ISR D17185318171
0/60 barback flangeRF100ISR D17185319171
0/100 barback flangeRF100ISR D17185320171
0/160 barback flangeRF100ISR D17185321171
0/250 barback flangeRF100ISR D17185322171
0/400 barback flangeRF100ISR D17185323171
0/600 barback flangeRF100ISR D17185324171
  • in-stock items
  • manufactured goods

Type
D1
Nominal size
100 - 100
accuracy class (EN 837-1/6)
1,0
ranges (EN 837-1/5)
see ordering table
application area
static load
≤ 600 bar:
Full scale value
> 600 bar:
¾ x full scale value
dynamic load
≤ 600 bar:
0.9 x full scale value
> 600 bar:
⅔ x full scale value
short-term
≤ 600 bar:
1.3 x full scale value
> 600 bar:
Full scale value
Operating temperature range
Medium:
max. 60 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,4 %/10 K,
falling temperature approx. ± 0.4 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
IP 54 (EN 60529) with housing vent (≤ 25 bar)

Standard design

Connection
Brass, bottom
Measuring element
Bourdon tube
≤ 60 bar:
"C" type tube, Copper alloy
> 60 bar:
helical tube, stainless steel 316 Ti/316 L
movement
Brass
Dial
Aluminium, weiß
Scaling black
Pointer
Aluminium, schwarz
Housing
Kunststoff (PA 6.6 GB30), with blow-out
Screw type bezel
Kunststoff (PA 6.6 GB30)
window
Sicherheitsverbundglas

Click the corresponding image for detail views, additional information and dimension tables.

854_017_0336-00.PDF

Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck

PDF