Skip to main content

RF63GT D302

Rohrfeder-Standardmanometer für die Gastechnik Typ D3

housing ⌀ (nominal size)63 mm
ConnectionG¼B
alignmentbottom
accuracy class1,6
standardEN 837-1-S2

  • Version safety pressure gauge S2 as per EN 837-1
  • dual scale for measurement of different media (option)
  • rear blow-out
  • many customised versions available

For gaseous and liquid media which are not highly viscous and do not crystallise. Specially designed for gas technology devices, fittings and installations.
! For measuring gas or vapour, these gauges must be used in accordance with the table "Selection Criteria as per EN 837-2" (see appendix)!

RangeMounting typeTypePart number
-1/0 bardirectRF63GT D30285101302GT
-1/0.6 bardirectRF63GT D30285102302GT
-1/+1.5 bardirectRF63GT D30285103302GT
-1/+3 bardirectRF63GT D30285104302GT
-1/+5 bardirectRF63GT D30285105302GT
-1/+9 bardirectRF63GT D30285106302GT
-1/+15 bardirectRF63GT D30285107302GT
0/0.6 bardirectRF63GT D30285109302GT
0/1 bardirectRF63GT D30285110302GT
0/1.6 bardirectRF63GT D30285111302GT
0/2.5 bardirectRF63GT D30285112302GT
0/4 bardirectRF63GT D30285113302GT
0/6 bardirectRF63GT D30285114302GT
0/10 bardirectRF63GT D30285115302GT
0/16 bardirectRF63GT D30285116302GT
0/25 bardirectRF63GT D30285117302GT
0/40 bardirectRF63GT D30285118302GT
0/60 bardirectRF63GT D30285119302GT
0/100 bardirectRF63GT D30285120302GT
0/160 bardirectRF63GT D30285121302GT
0/250 bardirectRF63GT D30285122302GT
0/400 bardirectRF63GT D30285123302GT
0/315 bardirectRF63GT D30285129302GT
  • in-stock items
  • manufactured goods

Type
D3
Nominal size
63 - 63
Version
EN 837-1-S2
accuracy class (EN 837-1/6)
1,6
ranges (EN 837-1/5)
see ordering table
application area
static load:
¾ x full scale value
dynamic load:
⅔ x full scale value
short-term:
Full scale value
Operating temperature range
Medium:
max. 60 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,4 %/10 K,
falling temperature approx. ± 0.4 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
IP 32 (EN 60529)

Standard design

Connection
D302: stainless steel 316 Ti/316 L
bottom
Measuring element
Bourdon tube
D302: stainless steel 316 Ti/316 L
≤ 40 bar:
"C" type tube
> 40 bar:
helical tube
movement
Brass
Dial
Aluminium, weiß
Scaling black
Pointer
Aluminium, schwarz
Housing
Edelstahl 304, with rear blow-out
window
Kunststoff, fest eingeschnappt

Click the corresponding image for detail views, additional information and dimension tables.

AFRISO_SELECTION_PRESSURE_GAUGES_EN837-2_EN_11-16.PDF

Auswahlkriterien und Sicherheitsaspekte für Druckmessgeräte nach EN 837-2

PDF
854_017_0336-00.PDF

Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck

PDF