Skip to main content

RF63Si D402

Rohrfeder-Sicherheitsmanometer Typ D4

housing ⌀ (nominal size)63 mm
ConnectionG¼B
alignmentbottom
accuracy class1,6
standardEN 837-1

  • Safety housing S3 as per EN 837-1/9.7.2
  • measuring system fully welded to housing
  • tightness-tested with helium
  • DNV- and GOSSTANDART-certified
  • Ex version (optional)

For corrosive gaseous and liquid media which are not highly viscous and do not crystallise; suitable for corrosive environments. This gauge is designed for applications as per EN 837-1/9.7.2.

RangeMounting typeTypePart number
-1/0 bardirectRF63Si D40285401402
-1/0.6 bardirectRF63Si D40285402402
-1/+1.5 bardirectRF63Si D40285403402
-1/+3 bardirectRF63Si D40285404402
-1/+5 bardirectRF63Si D40285405402
-1/+9 bardirectRF63Si D40285406402
-1/+15 bardirectRF63Si D40285407402
0/0.6 bardirectRF63Si D40285409402
0/1 bardirectRF63Si D40285410402
0/1.6 bardirectRF63Si D40285411402
0/2.5 bardirectRF63Si D40285412402
0/4 bardirectRF63Si D40285413402
0/6 bardirectRF63Si D40285414402
0/10 bardirectRF63Si D40285415402
0/16 bardirectRF63Si D40285416402
0/25 bardirectRF63Si D40285417402
0/40 bardirectRF63Si D40285418402
0/60 bardirectRF63Si D40285419402
0/100 bardirectRF63Si D40285420402
0/160 bardirectRF63Si D40285421402
0/250 bardirectRF63Si D40285422402
0/400 bardirectRF63Si D40285423402
  • in-stock items
  • manufactured goods

Type
D4
Nominal size
63 - 63
accuracy class
EN 837-1/6
NG 63, ≤ 400 bar: 1,6
ranges (EN 837-1/5)
see ordering table
NG 100, NG 160
static load
dynamic load
short-term
Operating temperature range
Medium:
max. 100 °C
Ambient:
-20/+60 °C
Degree of protection
IP 54 (EN 60529)

Standard design

Connection
Stainless steel 316 L, bottom
Measuring element
Bourdon tube
stainless steel 316 Ti/316 L
≤ 60 bar:
"C" type tube
> 60 bar:
helical tube
tightness-tested with helium
movement
Stainless steel
Dial
Aluminium, weiß
Scaling black
Pointer
Aluminium, schwarz
Housing
Edelstahl 304, with solid baffle wall and blow-out (S3)
bayonet bezel
Edelstahl 304
window
Sicherheitsverbundglas

Click the corresponding image for detail views, additional information and dimension tables.

AFRISO_SELECTION_PRESSURE_GAUGES_EN837-2_EN_11-16.PDF

Auswahlkriterien und Sicherheitsaspekte für Druckmessgeräte nach EN 837-2

PDF
854_017_0336-00.PDF

Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck

PDF