CAPBs® set Heating system check sens

Afriso CAPBs® set Heating system check sens
Data sheet CAPBs® set Heating system check sens
Afriso Data sheet CAPBs® set Heating system check sens

Versions

DG PG Part no. Price (€)* Remember
CAPBs® set Heating system check sens H 4 560009 467.63

* prices plus applicable VAT    Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet CAPBs® set Heating system check sens Data sheet PDF
Afriso Data sheet CAPBs® set Heating system check sens
Ready-to-be-used set in system case S with sensor module pressure/temperature CAPBs® sens FP 10 (20 mbar), Pitot tube and surface temperature probe. The measured data is used to calculate the ventilation loss. If the channel cross section is known, it is possible to calculate the volume flow. The measurement results of the surface temperature probe serve as the basis for calculating the surface loss of the heat generator.
Dimensions (W x H x D)
Sensor module:
42 x 74 x 35 mm
Case:
260 x 63 x 155 mm
Weight
0.4 kg
Measuring range
Pressure:
-20/+20 mbar
Temperature:
-50/+600 °C
Pitot:
0.2/20 m/s
Accuracy
Pressure:
± 0.003 mbar (< 0.6 bar)
± 0.5 % v. Mw. ± 1 Digit (> 0.6 mbar)
Temperature:
± 1.5 K
Pitot:
± 0.1 m/s (< 2 m/s)
± 5 % v. Mw. (> 2 m/s)
Resolution
Pressure:
0.001 mbar
Temperature:
0.1 °C
Pitot:
0.1 m/s
Indication of measured values
hPa, mbar, Pa, mmWs, mmHg, inHg
Scope of delivery
  • Pressure transmitter CAPBs<sup>®</sup> sens FP 10 (20 mbar)
  • Pitot tube EP-SR 10
  • Surface temperature probe TFB-OF 120
  • System case S