Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview Fuel oil components Fuel oil components Overview Fast and clean oil filter change Avoiding fungal attacks in biofuel More performance with the sintered plastic sieve AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway Produkte Sicherheit Komfort Raumklima AFRISOhome App Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home Craft 4.0 Craft 4.0 Overview EUROLYZER® CAPBs®-Sets CAPBs®-Sets Overview App OEM-Manifold systems Hydraulic Balancing Hydraulic Balancing Overview Vario-DP Tank conversion Hygienic processes AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search Domestic technology Equipment for heating systems, boiler rooms and chimneys WZB-1 "Chimney connection" always above flue connection "Flue gas connection" with pipe connection piece Images 2 WZB-1 Kaminzugbegrenzer Variants Documents Benefits saves heating costs, optimises combustion and keeps the chimney draft constantfor stabilising the chimney draftfor oil, gas or solid fuel systems Application The draft stabiliser for oil, gas or solid fuel systems keeps chimney draft constant and the chimney dry. Suitable for connection to flue gas pipes with ∅ 120 to 200 mm by means of pipe connection pieces or to brickwork chimneys or chimneys with several walls by means of special connection pieces. Description Draft stabiliser made of galvanised sheet steel with flap. The flap is set by means of a rotary knob acting on a weight for precise adjustment. Depending on the adjustment of the weight, the flap admits more or less secondary air into the chimney when the vacuum gets too high.The natural chimney draft is approx. 20 to 50 Pa, depending on the height and the cross section of the chimney as well as the weather conditions. These values increase when the temperature increases. The draft stabiliser allows for setting the vacuum required by the manufacturer of the heating system (oil or gas burner/boiler combination, oil or gas furnace, etc.) and keeps this vacuum almost constant. Correct chimney draft is a prerequisite for an optimum combustion process and contributes to a reduction in heating costs.The draft stabiliser performs the following functions:It limits the vacuum to the required value.It keeps the chimney dry and prevents soot deposits. Variants Technical data Downloads Variants Part no.Draft stabiliser WZB-169760 in-stock items manufactured goods Technical data Adjustment range (draft requirements):10/26 PaApplication areaheight: bis 20 mchimney group I/II: bis 400 cm²chimney group III: bis 500 cm²Operating temperature rangeflue gas: max. 400 °CMounting positionFlap axis horizontalRegelscheibe senkrechtTightness< 3 m³/h < at ∆p 10 Pa Downloads Kaminzugbegrenzer WZB-1 Manuals PDF Download Related products
AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
"Chimney connection" always above flue connection "Flue gas connection" with pipe connection piece Images 2 WZB-1 Kaminzugbegrenzer Variants Documents Benefits saves heating costs, optimises combustion and keeps the chimney draft constantfor stabilising the chimney draftfor oil, gas or solid fuel systems Application The draft stabiliser for oil, gas or solid fuel systems keeps chimney draft constant and the chimney dry. Suitable for connection to flue gas pipes with ∅ 120 to 200 mm by means of pipe connection pieces or to brickwork chimneys or chimneys with several walls by means of special connection pieces. Description Draft stabiliser made of galvanised sheet steel with flap. The flap is set by means of a rotary knob acting on a weight for precise adjustment. Depending on the adjustment of the weight, the flap admits more or less secondary air into the chimney when the vacuum gets too high.The natural chimney draft is approx. 20 to 50 Pa, depending on the height and the cross section of the chimney as well as the weather conditions. These values increase when the temperature increases. The draft stabiliser allows for setting the vacuum required by the manufacturer of the heating system (oil or gas burner/boiler combination, oil or gas furnace, etc.) and keeps this vacuum almost constant. Correct chimney draft is a prerequisite for an optimum combustion process and contributes to a reduction in heating costs.The draft stabiliser performs the following functions:It limits the vacuum to the required value.It keeps the chimney dry and prevents soot deposits. Variants Technical data Downloads Variants Part no.Draft stabiliser WZB-169760 in-stock items manufactured goods Technical data Adjustment range (draft requirements):10/26 PaApplication areaheight: bis 20 mchimney group I/II: bis 400 cm²chimney group III: bis 500 cm²Operating temperature rangeflue gas: max. 400 °CMounting positionFlap axis horizontalRegelscheibe senkrechtTightness< 3 m³/h < at ∆p 10 Pa Downloads Kaminzugbegrenzer WZB-1 Manuals PDF Download