Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. We strive to improve the environment, to make processes which work with greater environmental compatibility and to avoid putting a strain on the environment. We offer you a multitude of innovative solutions, new products and smart concepts. More Informations Industries & Topics Industries & Topics Overview Fuel oil components Fuel oil components Overview Fast and clean oil filter change Avoiding fungal attacks in biofuel More performance with the sintered plastic sieve AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview AFRISOhome App Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home Craft 4.0 Craft 4.0 Overview OEM-Manifold systems Hydraulic Balancing Hydraulic Balancing Overview VarioQ Vario-DP Tank conversion Hygienic processes AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search Domestic technology Equipment for surface heating and cooling systems 77490 Pumpengruppe PrimoTherm Floor 130 Images 1 Back PrimoTherm® Floor 130 | 77490 Pumpengruppe für Verteilersysteme in-stock items Documents Benefits pre-assembled and tightness-tested assemblyFlow temperature fully adjustable between 35 and 60 °CMixing valve cap with window and scale, can be lead-sealed (ideal for public facilities)with shut-off ball valves Application Pump assembly for constant control of the flow temperature of water-based surface heating systems. With the integrated thermostatic mixing valve, the flow temperature can be adjusted to a desired temperature by adding water from the return. Due to the eccentrical screw connection with variable distance, PrimoTherm is suitable for almost all manifold systems. Description Complete, pre-assembled and tightness-tested pump assembly with all required functional components, including shut-off ball valve DN 20. The required flow temperature is set within a range from 35 to 60 °C at the thermostatic mixing valve mixing valve ATM 563. A cover that can be lead-sealed protects the control knob against improper adjustments during operation. The selected adjustment is visible through the window in the cap. The special chamber geometry also helps to avoid damage caused by overpressure during closing (backflow preventer to return).The circulation pump automatically switches off if a safety-related temperature limitation is exceeded. It is adjustable between 20 to 60 °C; the factory setting is 55 °C. This helps to prevent damage to the underfloor heating system. The pump features the following operating modes:Constant volume flowConstant pressureVenting function of pump housingIn venting mode, the entire surface heating/cooling system can be conveniently vented by means of the valve integrated in the pump assembly and the enclosed vent hose. Technical data Downloads Technical data system connectionsBoiler: G¾ femaleManifolds: G1 maleOperating temperature rangeMedium: max. 90 °CMedium: short-term 110 °CSystem pressuremax. 6 barmax.Flow coefficient Kvs2.5 m³/hDimensionsW x H x D: 200 x 370 x 88 mmthermostatic mixing valveATM 563Adjustment range: 35/60 °CHousing: brass (CW626N), dezincification-resistantcap: Plastic (ABS/PBT)control knob: Plastic (ABS/PBT)seals: EPDMCirculation pumpWILO Yonos PARA 15/6 RKA 130Length: 130 mmDegree of protection: IP 44 (EN 60529)Supply voltage: AC 230 V, 50 Hzpumping volume: max. 3.3 m³/hpumping head: max. 6 mOptionsother circulation pumps Downloads Pumpengruppe PrimoTherm® Floor 130 Manuals PDF Download Related products
AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Search
Images 1 Back PrimoTherm® Floor 130 | 77490 Pumpengruppe für Verteilersysteme in-stock items Documents Benefits pre-assembled and tightness-tested assemblyFlow temperature fully adjustable between 35 and 60 °CMixing valve cap with window and scale, can be lead-sealed (ideal for public facilities)with shut-off ball valves Application Pump assembly for constant control of the flow temperature of water-based surface heating systems. With the integrated thermostatic mixing valve, the flow temperature can be adjusted to a desired temperature by adding water from the return. Due to the eccentrical screw connection with variable distance, PrimoTherm is suitable for almost all manifold systems. Description Complete, pre-assembled and tightness-tested pump assembly with all required functional components, including shut-off ball valve DN 20. The required flow temperature is set within a range from 35 to 60 °C at the thermostatic mixing valve mixing valve ATM 563. A cover that can be lead-sealed protects the control knob against improper adjustments during operation. The selected adjustment is visible through the window in the cap. The special chamber geometry also helps to avoid damage caused by overpressure during closing (backflow preventer to return).The circulation pump automatically switches off if a safety-related temperature limitation is exceeded. It is adjustable between 20 to 60 °C; the factory setting is 55 °C. This helps to prevent damage to the underfloor heating system. The pump features the following operating modes:Constant volume flowConstant pressureVenting function of pump housingIn venting mode, the entire surface heating/cooling system can be conveniently vented by means of the valve integrated in the pump assembly and the enclosed vent hose. Technical data Downloads Technical data system connectionsBoiler: G¾ femaleManifolds: G1 maleOperating temperature rangeMedium: max. 90 °CMedium: short-term 110 °CSystem pressuremax. 6 barmax.Flow coefficient Kvs2.5 m³/hDimensionsW x H x D: 200 x 370 x 88 mmthermostatic mixing valveATM 563Adjustment range: 35/60 °CHousing: brass (CW626N), dezincification-resistantcap: Plastic (ABS/PBT)control knob: Plastic (ABS/PBT)seals: EPDMCirculation pumpWILO Yonos PARA 15/6 RKA 130Length: 130 mmDegree of protection: IP 44 (EN 60529)Supply voltage: AC 230 V, 50 Hzpumping volume: max. 3.3 m³/hpumping head: max. 6 mOptionsother circulation pumps Downloads Pumpengruppe PrimoTherm® Floor 130 Manuals PDF Download