Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. We strive to improve the environment, to make processes which work with greater environmental compatibility and to avoid putting a strain on the environment. We offer you a multitude of innovative solutions, new products and smart concepts. More Informations Industries & Topics Industries & Topics Overview Fuel oil components Fuel oil components Overview Fast and clean oil filter change Avoiding fungal attacks in biofuel More performance with the sintered plastic sieve AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview AFRISOhome App Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home Craft 4.0 Craft 4.0 Overview OEM-Manifold systems Hydraulic Balancing Hydraulic Balancing Overview VarioQ Vario-DP Tank conversion Hygienic processes AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Schulungen & Trainings Schulungen & Trainings Overview Heizen mit flüssigen Brennstoffen Inhouse-Schulung - Heizen mit flüssigen Brennstoffen Inhouse-Schulung Heizölverbraucheranlagen Smart Home Experte Search Domestic technology Level sensors, overfill prevention systems and level controllers 53310 Messumformer LS 500 AC 230V Images 3 Back LS 500 | 53310 Messumformer für Überfüllsicherung LS für Ex (WHG) in-stock items Benefits compact transducer in wall mounting housingtype-approved together with the level probes LS 300 EU, LS 300 FU oder LS 300 ESPU as part of an overfill prevention systemsupply voltage AC 24 V or DC 24 V (option)connection of additional alarm unit ZAG 01 possibleEx approval Application To avoid overfilling of stationary tanks and stationary-use tanks. Approved without list of substances for water-polluting liquids, also with flash point < 55 °C. The overfill prevention system must be set up in such a way that visual and audible alarms are triggered when the maximum permissible level is reached. The transducer must be installed outside of the hazardous area. Description Transducer with test button. Type-approved together with the level probes LS 300 EU, LS 300 FU or LS 300 ESPU as part of an overfill prevention system. The transducer supplies the level probe via an intrinsically safe circuit, evaluates the change in resistance of the PTC thermistor, continuously checks the PTC thermistor operation and monitors the system (power outage, short circuit, line interruption, etc.). Negative results cause the overfill prevention system to respond. The additional alarm unit ZAG 01 can also be connected. Technical data Accessories Technical data Operating temperature rangeAmbient: -25/+50 °CSupply voltageAC 230 VNominal powermax. 4 VASwitching outputRelay contact: 1 x voltage-free changeover contactSensor current circuit (intrinsically safe)voltage: < DC 15.8 VCurrent: < 154 mApower: < 600 mWHousingWall mounting housingW x H x D: 75 x 150 x 110 mmapprovalDIBt: Z-65.11-228EU type examination certificateTÜV 00 ATEX 1641 Ex II (1)G [Ex ia] IICOptionsupply voltage DC 24 V or AC 24 V at extra charge Accessories Level sensors, overfill prevention systems and level controllers Abb. Bezeichnung LS 300 EU | 53300 Related products
AFRISO Smart Home AFRISO Smart Home offers innovative solutions for intelligent home automation. With modern sensors and actuators, you can easily and conveniently control your home. More Informations Service-Center Service-Center Overview Service Contact persons Data exchange formats Catalogs Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Schulungen & Trainings Schulungen & Trainings Overview Heizen mit flüssigen Brennstoffen Inhouse-Schulung - Heizen mit flüssigen Brennstoffen Inhouse-Schulung Heizölverbraucheranlagen Smart Home Experte Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Training & Events Training & Events Overview Exhibitions Exhibitions Overview SHK+E 2026, Essen IFH Intherm 2026, Nuremberg GET Nord 2026, Hamburg Schulungen & Trainings Schulungen & Trainings Overview Heizen mit flüssigen Brennstoffen Inhouse-Schulung - Heizen mit flüssigen Brennstoffen Inhouse-Schulung Heizölverbraucheranlagen Smart Home Experte Search
Images 3 Back LS 500 | 53310 Messumformer für Überfüllsicherung LS für Ex (WHG) in-stock items Benefits compact transducer in wall mounting housingtype-approved together with the level probes LS 300 EU, LS 300 FU oder LS 300 ESPU as part of an overfill prevention systemsupply voltage AC 24 V or DC 24 V (option)connection of additional alarm unit ZAG 01 possibleEx approval Application To avoid overfilling of stationary tanks and stationary-use tanks. Approved without list of substances for water-polluting liquids, also with flash point < 55 °C. The overfill prevention system must be set up in such a way that visual and audible alarms are triggered when the maximum permissible level is reached. The transducer must be installed outside of the hazardous area. Description Transducer with test button. Type-approved together with the level probes LS 300 EU, LS 300 FU or LS 300 ESPU as part of an overfill prevention system. The transducer supplies the level probe via an intrinsically safe circuit, evaluates the change in resistance of the PTC thermistor, continuously checks the PTC thermistor operation and monitors the system (power outage, short circuit, line interruption, etc.). Negative results cause the overfill prevention system to respond. The additional alarm unit ZAG 01 can also be connected. Technical data Accessories Technical data Operating temperature rangeAmbient: -25/+50 °CSupply voltageAC 230 VNominal powermax. 4 VASwitching outputRelay contact: 1 x voltage-free changeover contactSensor current circuit (intrinsically safe)voltage: < DC 15.8 VCurrent: < 154 mApower: < 600 mWHousingWall mounting housingW x H x D: 75 x 150 x 110 mmapprovalDIBt: Z-65.11-228EU type examination certificateTÜV 00 ATEX 1641 Ex II (1)G [Ex ia] IICOptionsupply voltage DC 24 V or AC 24 V at extra charge Accessories Level sensors, overfill prevention systems and level controllers Abb. Bezeichnung LS 300 EU | 53300