HY 80 | 63575

Hydrometer für Heizung/Sanitär

in-stock items

Nominal size
80 - 80
accuracy class (EN 837-1/6)
2,5
ranges
0/10 bar
application area
static load:
¾ x full scale value
dynamic load:
⅔ x full scale value
short-term:
Full scale value
Operating temperature range
Medium:
max. 60 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,4 %/10 K,
falling temperature approx. ± 0.4 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
IP 32 (EN 60529)

Standard design

Connection
Brass, bottom
NG 80: G½B
Measuring element
Bourdon tube, "C" type tube
Copper alloy
movement
Brass
Dial
Kunststoff, weiß
dual scale bar outer - mWC inner
Scaling black
Pointer
Kunststoff, schwarz
Housing
Kunststoff (ABS), schwarz, highly impact-resistant and corrosion-resistant
window
Kunststoff, eingeclipst
with adjustable red reference pointer