Skip to main content
Back

DMU 02 | 32810

Druckmessumformer Industrieausführung

in-stock items

Measuring range0/2.5 bar
ConnectionG½B
ConnectionEN 837-1/7.3
Electrical connectionConnector and junction box as per ISO 4400 (DIN 43650-A)
Part no.32810

  • extremely resistant to shock, pulsation and vibration
  • high overload safety
  • best dynamic pressure resistance at high load changes
  • wetted area without seals due to welding
  • no transmission liquid

For electronic pressure measurement in industrial applications, e.g. hydraulic, pneumatic, gas industry, refrigeration, automation, medical, as well as general mechanical and plant engineering applications.

Pressure transducers convert physical pressure into an electrical signal proportional to the pressure. DMU 02 is equipped with a piezo-resistive polysilicon thin-film measuring cell.

Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
< ± 0.5 % FSO
Measuring range
see ordering table
Overpressure safety
≤ 250 bar: at least 2 x FS
Burst pressure
≤ 250 bar: at least 3 x FS
Operating temperature range
Medium:
-40/+125 °C
Ambient:
-40/+105 °C
Storage:
-40/+125 °C
Temperature error band
≤ ± 0.15 % FSO/10 K ≤ ± In compensated range -25/+85 °C
dynamic characteristics
Response time:
< 1 ms
Process connection
G½B EN 837-1/7.3
material
Housing:
Stainless steel 304
pressure connection:
Stainless steel 304
electr. measuring cell:
Stainless steel 630/304
Supply voltage
DC 10 − 32 V
Output signal
2-wire, 4–20 mA
Load
Rmax = [(UB – UBmin)/0.02 A] Ω
Current input
< 25 mA
electrical protection
short circuit proof and protected against reverse polarity
Electrical connection
Connector and junction box as per ISO 4400 (DIN 43650-A)
Degree of protection
IP 65 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU
Pressure Equipment Directive 2014/68/EU