Bourdon tube pressure gauge

housing ⌀ (nominal size)63 mm
Connection¼-18 NPT
alignmentbottom
accuracy class1,6

RangeMounting typeTypePart number
-1/0.6 bardirectRF63RG IK2 D30287302302
-1/+1.5 bardirectRF63RG IK2 D30287303302
-1/+3 bardirectRF63RG IK2 D30287304302
-1/+5 bardirectRF63RG IK2 D30287305302
-1/+9 bardirectRF63RG IK2 D30287306302
-1/+15 bardirectRF63RG IK2 D30287307302
0/1.6 bardirectRF63RG IK2 D30287311302
0/2.5 bardirectRF63RG IK2 D30287312302
0/4 bardirectRF63RG IK2 D30287313302
0/6 bardirectRF63RG IK2 D30287314302
0/10 bardirectRF63RG IK2 D30287315302
0/16 bardirectRF63RG IK2 D30287316302
0/25 bardirectRF63RG IK2 D30287317302
0/40 bardirectRF63RG IK2 D30287318302
0/60 bardirectRF63RG IK2 D30287319302
0/100 bardirectRF63RG IK2 D30287320302
0/160 bardirectRF63RG IK2 D30287321302
0/250 bardirectRF63RG IK2 D30287322302
0/400 bardirectRF63RG IK2 D30287323302
  • in-stock items
  • manufactured goods

Type
D3
Nominal size
63 - 63
accuracy class (EN 837-1/6)
1,6
ranges
see ordering table
Calibration medium
Nitrogen or dried air
application area
static load:
¾ x full scale value
dynamic load:
⅔ x full scale value
short-term:
Full scale value
contact types
inductive contact (IK)
minimum range
Contact
IK dual:
Medium:
max. 150 °C
Ambient:
-20/+60 °C
Temperature performance
Indication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:
bei Temperaturzunahme ca. ± 0,4 %/10 K,
falling temperature approx. ± 0.4 %/10 K
vom jeweiligen Skalenendwert
Degree of protection
IP 32 (EN 60529)

Standard design

Connection
stainless steel 316 Ti/316 L, bottom
Measuring element
Bourdon tube, stainless steel 316 Ti/316 L
≤ 60 bar:
"C" type tube
> 60 bar:
helical tube
wetted parts
cleaned,
mit Stickstoff gespült,
electropolished,
Oberflächenrauhigkeit ≤ Ra 0,6 µm
movement
Stainless steel
Dial
Aluminium, weiß
Scaling:
black
label:
ultra-pure gas
Pointer
Aluminium, schwarz
Housing
Edelstahl 304 back blow-out
push on bezel
Edelstahl 304, blank
window
Kunststoff
Magnetic spring contact (MK)
Inductive contact (IK)
Supply voltage
DC 5 V DC 25 V
Current input
≥ 2.1 mA
Switching accuracy
approx. 0.5 % of full scale value
Operating temperature range
-20/+70 °C or corresponding to the respective measuring instruments
Adjustment range
5–95 % measuring range of gauge
Options
  • contact systems with safety integrity level SIL 2

Click the corresponding image for detail views, additional information and dimension tables.

854_017_0336-00.PDF

Rohrfeder-, Kapselfeder-, Plattenfeder-, Membranfedermanometer für Differenzdruck