Back

MAXISYSTEM ST | M05100210

with gas treatment system

manufactured goods

  • automatic sensor regeneration via fresh air valve allows for convenient long-term measurements of up to 12 hours
  • optionally with humidity sensor for sensor protection
  • smart system protection by means of continuous monitoring of fresh air valve, heated line, cooler and humidity sensor
  • particularly suitable for industrial applications due to the robust, light.weight design (7.5 kg)
  • Large range of probes: Heated line including draft and flue gas temperature, - Modular probe system, high-temperature probes
  • automatic zero point for convenient and fast measurement preparation

Gas treatment system specially for mobile applications. Whenever high-precision gas analysis is required where the flue gas may contain pollution and condensate, MAXISYSTEM ST is the system of choice. In the analysis of highly water-soluble gases such as NO2 and SO2, MAXISYSTEM ST must be used in order to be able to obtain reliable measurement results.

The modular measurement concept allows to use the corresponding flue gas analyser MULTILYZER STx as a "stand-alone device" or in conjunction with MAXISYSTEM ST. With the integrated temperature controller, the temperature of the heated line can be optimally adjusted to the application between 100 °C and 180 °C. Flue gas analysis, draft/differential pressure and flue gas temperature are directly measured. Efficiency, flue gas loss and dew point are calculated in real time. The operating state of the measuring device can be checked via the status indication of the heated line and the gas cooler. The condensate outlet integrated in the housing reliably discharges condensate. MAXISYSTEM ST is designed for quasi-continuous operation with an operating time of up to 12 hours.

Einsatzmedien

Operating temperature range
Ambient:
5/40 °C
Storage:
-20/+50 °C
Gas outlet dew point:
Factory setting:
5 °C
heated sampling line
adjustable:
100/180 °C
alarm threshold
± 3 K around dew point of gas cooler or temperature of sampling line
nominal cooling capacity
  72 kJ/h   at 25 °C
Supply voltage
AC 230 V, 50/60 Hz
wetted parts
Stainless steel, PTFE, PVDF, Silikon, fluoroelastomer, PA
Housing
W x H x D:
420 x 350 x 220 mm
Weight:
  7.5 kg ( )
Degree of protection:
IP 42 (EN 60529)
Interface
Bluetooth®

Modular probe system
Abb.
Bezeichnung
AWS-B
AWS-B | 510921
Condensate filter cartridges KFP
Abb.
Bezeichnung
Condensate filter cartridge KFP
Condensate filter cartridge KFP | 500190
Flue gas probes
Abb.
Bezeichnung
high-temperature flue gas combination probe
high-temperature flue gas combination probe | 500273-1
Thermal printer EUROprinter
Abb.
Bezeichnung
EUROprinter II
EUROprinter II | 524340
EUROprinter II
EUROprinter II | 524346
Humidity sensors
Abb.
Bezeichnung
Feuchte-Sensor MAXISYSTEM ST
Feuchte-Sensor MAXISYSTEM ST | 511180
Analysis lines
Abb.
Bezeichnung
ENL-MX
ENL-MX | 524437
Transport systems/cases
Abb.
Bezeichnung
Carrying bag
Carrying bag | 524651
Modular high-temperature probe system
Abb.
Bezeichnung
AWS-BHT
AWS-BHT | 510821
AWS-BHT