Skip to main content

HydroFox® DMU 08

Pressure transducers

  • compact and sturdy stainless steel design
  • special calibration for all standard pressure units possible
  • version with PUR or FEP cable
  • high measuring accuracy at excellent price/performance ratio
  • watertight up to 10 m water column - ideal for use in flood hazard areas
  • Optional Ex version

For electronic, continuous level measurement, e.g. in wells, drilling holes, water, containers or in waste water systems. Suitable for groundwater, drinking water, waste water (with optional FEP cable), diesel fuel, fuel oil; also for use in flood hazard areas.

The level indicators HydroFox® DMU 08 use silicon technology and feature calibrated, amplified sensor signals which are available as standardised voltage or current outputs.

Measuring rangeOverloadPart no.
HydroFox® DMU 08with 5 m PUR cable0/100 mbarat least 5 x FS31555
HydroFox® DMU 08with 5 m PUR cable0/160 mbarat least 6 x FS31556
HydroFox® DMU 08with 5 m PUR cable0/200 mbarat least 5 x FS31557
HydroFox® DMU 08with 5 m PUR cable0/250 mbarat least 4 x FS31558
HydroFox® DMU 08with 5 m PUR cable0/300 mbarat least 3 x FS31519
HydroFox® DMU 08with 5 m PUR cable0/400 mbarat least 5 x FS31559
HydroFox® DMU 08with 5 m PUR cable0/600 mbarat least 8 x FS31560
HydroFox® DMU 08with 5 m PUR cable0/1 barat least 5 x FS31561
HydroFox® DMU 08with 5 m PUR cable0/1.6 barat least 6 x FS31562
HydroFox® DMU 08with 5 m PUR cable0/2 barat least 4 x FS31563
HydroFox® DMU 08with 5 m PUR cable0/2.5 barat least 4 x FS31564
HydroFox® DMU 08with 5 m PUR cable0/4 barat least 5 x FS31565
HydroFox® DMU 08with 5 m PUR cable0/6 barat least 6 x FS31566
HydroFox® DMU 08with 5 m PUR cable0/10 barat least 4 x FS31567
HydroFox® DMU 08with 5 m PUR cable0/16 barat least 5 x FS31568
HydroFox® DMU 08with 5 m PUR cable0/20 barat least 3 x FS31569
HydroFox® DMU 08with 5 m PUR cable0/25 barat least 3 x FS31570
  • in-stock items
  • manufactured goods

Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
≤ 0/400 mbar < ± 0.5 % FSO
Measuring range
see ordering table
Operating temperature range
Medium:
-10/+70 °C
Ambient:
-10/+70 °C
Storage:
-25/+70 °C
Temperature error band
≤ 400 mbar: ≤ ± 1 % FSO/10 K ≤ ± In compensated range 0/70 °C
dynamic characteristics
Response time:
≤ 10 ms
Probe
L x ⌀:
117 x 24 mm
Weight:
  620 g
material
Housing:
Stainless steel 316 L
diaphragm:
Stainless steel 316 L
seals:
FKM (Viton)
cable:
PUR
pressure transmission liquid
Silicone oil
Supply voltage
DC 12 − 36 V
Output signal
4–20 mA, 2-wire
Load
Rmax = [(UB – UBmin)/0.02 A] Ω
Current input
< 25 mA
electrical protection
short circuit proof and protected against reverse polarity
Electrical connection
PUR cable with integrated breather tube for reference to the ambient atmospheric pressure
Cable length:
5 m
Degree of protection:
IP 68 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS-Richtlinie 2011/65/EU
Pressure Equipment Directive 2014/68/EU

USE-AND-RESISTANCE-OIL-COMPONENTS-FLYER.PDF

Beständigkeit Ölkomponenten

PDF
DMU01-03-04-05-08-08T.PDF

Druckmessumformer DMU 01, DMU 03, DMU 04, DMU 05, DMU 08, DMU 08T

PDF
Download
OPTIONEN_DMU07_BIS_DMU11D_596_EN.PDF

Druckmessumformer DMU 07/DMU 07 FG/DMU 08/DMU 08 T/DMU 09/ DMU 10 D/ DMU 11 D

PDF
HYDROFOX_DMU_08_EN_05-18.PDF

HydroFox DMU 08

PDF
900_100_0832.PDF

Tauchsonde DMU 08, DMU 08 T, DMU 09

PDF
900_100_0821.PDF

Tauchsonde DMU 08…Ex, DMU 09…Ex

PDF
AFRISO_DMU_MISURAZIONE_ELETTRONICA_IT_08-14.PDF

elektronische Druckmesstechnik - Druckmessumformer Serie DMU

PDF