Combustion controllers FR 1

Afriso Combustion controllers FR 1
Afriso Combustion controllers FR 1
Afriso Combustion controllers FR 1
Data sheet Combustion controllers FR 1
Afriso Data sheet Combustion controllers FR 1

Versions

Part no. Remember
Combustion controllers FR 1 42294

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Combustion controllers FR 1 Catalog page PDF
Afriso Data sheet Combustion controllers FR 1
Combustion controller FR 1 Operating instructions PDF
Afriso Combustion controller FR 1
The FR 1 combustion controller controls the combustion air supply. The temperature in the heat generator is detected by an integrated thermostat. The thermostat is connected to the air supply damper by means of a lever and a chain. The air supply is controlled by means of opening or closing the air supply damper, depending on the boiler flow temperature.
Operating temperature range
Medium:
Max. 115 °C
Ambient:
Max. 70 °C at switching button
Connection
G¾ male
Dimensions
Immersion pipe length:
53 mm
Chain length:
1.2 m
Chain load
100 – 600 g
Mounting position
Horizontal or vertical
Material
Housing:
Plastic
Stem:
Brass
Lever:
Steel, galvanised
Chain:
Steel, galvanised