Pressure transducers HydroFox® DMU 08 T Level probe

Afriso Pressure transducers HydroFox® DMU 08 T Level probe Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Legende: <div class="gallery-information"> <ol> <li>Junction box with pressure relief port</li> <li>Digital display unit DA 12</li> <li>Signalling device</li> <li>HydroFox<sup>®</sup> DMU 08</li> </ol> </div>
Afriso Pressure transducers HydroFox® DMU 08 T Level probe Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Legende: <div class="gallery-information"> <p> <strong>Junction box with pressure relief port</strong> </p> <p>Dimensions (in mm)</p> <ol> <li>Earth</li> <li>Cable gland</li> <li>Pressure compensation element</li> </ol> </div>
Afriso Pressure transducers HydroFox® DMU 08 T Level probe Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Legende: <div class="gallery-information"> <p> <strong>Anchor clamp</strong> </p> <p>Dimensions (in mm)</p> <ol> <li>Cable diameter</li> </ol> </div>
Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Pressure transducers HydroFox® DMU 08 T Level probe
Data sheet Pressure transducers HydroFox® DMU 08 T Level probe
Afriso Data sheet Pressure transducers HydroFox® DMU 08 T Level probe

Versions

Measuring range Overload Part no. Remember
HydroFox® DMU 08 T 0/100 mbar At least 5 x FS 31555T0070
HydroFox® DMU 08 T 0/160 mbar At least 6 x FS 31556T0070
HydroFox® DMU 08 T 0/200 mbar At least 4 x FS 31557T0070
HydroFox® DMU 08 T 0/250 mbar At least 4 x FS 31558T0070
HydroFox® DMU 08 T 0/300 mbar At least 4 x FS 31519T0070
HydroFox® DMU 08 T 0/400 mbar At least 5 x FS 31559T0070
HydroFox® DMU 08 T 0/600 mbar At least 8 x FS 31560T0070
HydroFox® DMU 08 T 0/1 bar At least 5 x FS 31561T0070
HydroFox® DMU 08 T 0/1.6 bar At least 6 x FS 31562T0070
HydroFox® DMU 08 T 0/2 bar At least 4 x FS 31563T0070
HydroFox® DMU 08 T 0/2.5 bar At least 4 x FS 31564T0070
HydroFox® DMU 08 T 0/4 bar At least 5 x FS 31565T0070
HydroFox® DMU 08 T 0/6 bar At least 6 x FS 31566T0070
HydroFox® DMU 08 T 0/10 bar At least 4 x FS 31567T0070
HydroFox® DMU 08 T 0/16 bar At least 5 x FS 31568T0070
HydroFox® DMU 08 T 0/20 bar At least 3 x FS 31569T0070
HydroFox® DMU 08 T 0/25 bar At least 3 x FS 31570T0070

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Pressure transducers HydroFox® DMU 08 T Level probe Data sheet PDF
Afriso Data sheet Pressure transducers HydroFox® DMU 08 T Level probe
Submersible probe DMU 08, DMU 08 T, DMU 09 Operating instructions PDF
Afriso Submersible probe DMU 08, DMU 08 T, DMU 09
Electronic pressure measurement - pressure transducers DMU series Product range industrial technology PDF
Afriso Electronic pressure measurement - pressure transducers DMU series
Enquiry pressure transducers DMU Checklists PDF
Afriso Enquiry pressure transducers DMU
Pressure transducers HydroFox® DMU 08 convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 08 uses a piezo-resistive silicon measuring cell.
Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
≤ 0/400 mbar < ± 0.5 % FSO
> 0/400 mbar < ± 0.35 % FSO
Measuring range
See ordering table
Operating temperature range
Medium:
-10/+70 °C
Ambient:
-10/+70 °C
Storage:
-25/+70 °C
Temperature error band
≤ 400 mbar:
≤ ± 1 % FSO In compensated range 0/70 °C
> 400 mbar:
≤ ± 0.75 % FSO In compensated range 0/70 °C
Dynamic characteristics
Response time:
≤ 10 ms
Probe
L x ⌀:
129 x 26.5 mm
Material
Housing:
Stainless steel 316 L
Diaphragm:
Stainless steel 316 L
Seals:
FKM (Viton)
Cable:
PUR
Pressure transmission liquid
Silicone oil
Supply voltage
DC 10 – 30 V
Output signal
4–20 mA, 2-wire
Load
R<sub>Max</sub> = [(UB – UB<sub>Min</sub>)/0.02 A] Ω
Current input
< 25 mA
Electrical protection
Short circuit proof and protected against reverse polarity
Electrical connection (PUR cable with integrated breather tube for reference to the ambient atmospheric pressure)
Cable length:
5 m
Degree of protection:
IP 68 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU

Options

  • FEP cable
  • Other measuring ranges
  • Screw connector kit
  • Junction box
  • Anchor clamp
  • Extended weight
Junction box with pressure relief port
Junction box with pressure relief port
Afriso
Dimensions (in mm)
  1. Earth
  2. Cable gland
  3. Pressure compensation element
Anchor clamp
Anchor clamp
Afriso
Dimensions (in mm)
  1. Cable diameter
DMU 08 T - standard version
DMU 08 T - standard version
Afriso
Dimensions (in mm)
Screw connector kit
Screw connector kit
Afriso
wiring diagram
wiring diagram
Afriso
2-wire, 4-20 mA