Data sheet PulsFox® PMG 20
Afriso Data sheet PulsFox® PMG 20

Versions

Part no. Remember
PulsFox® PMG 20 MO -00 5654000O-L-101
PulsFox® PMG 20 MO -00 5654000D-L-101
PulsFox® PMG 20 MS -20 5654020O-L-101
PulsFox® PMG 20 MS -21 5654021O-L-101
PulsFox® PMG 20 MS -22 5654022O-L-101
PulsFox® PMG 20 MS -23 5654023O-L-101
PulsFox® PMG 20 MS -20 5654020D-L-101
PulsFox® PMG 20 MS -21 5654021D-L-101
PulsFox® PMG 20 MS -22 5654022D-L-101
PulsFox® PMG 20 MS -23 5654023D-L-101
PulsFox® PMG 20 KX -40 5654040O-L-101
PulsFox® PMG 20 KX -40 5654040D-L-101
PulsFox® PMG 20 MF -60 5654060O-L-101
PulsFox® PMG 20 MF -61 5654061O-L-101
PulsFox® PMG 20 MF -62 5654062O-L-101
PulsFox® PMG 20 MF -63 5654063O-L-101
PulsFox® PMG 20 MF -60 5654060D-L-101
PulsFox® PMG 20 MF -61 5654061D-L-101
PulsFox® PMG 20 MF -62 5654062D-L-101
PulsFox® PMG 20 MF -63 5654063D-L-101

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet PulsFox® PMG 20 Data sheet PDF
Afriso Data sheet PulsFox® PMG 20
Measuring and control technology for hygienic processes Product range industrial technology PDF
Afriso Measuring and control technology for hygienic processes
Enquiry level measurement Level indicators and level controllers PDF
Afriso Enquiry level measurement
PulsFox® PMG 20 level indicators operate on the basis of the guided micropulse principle (TDR, time domain reflectometry). A micropulse is emitted along a probe. The micropulse is surrounded by an electromagnetic field. Reflections of the pulses from objects and surfaces serve as the basis of distance measurement. The pulse's propagation time is directly proportional to the distance between the probe and the surface of the medium. The reflectance of materials depends on the dielectric constant ɛr. Changes of the medium such as, for example vapour, dust or a turbulent surface do not affect the measuring accuracy of this measuring principle. No recalibration is required when a different medium is used. Even if properties such as pressure, temperature and density change, the system operates with high reliability and precision. PulsFox® PMG 20 has no moving parts and is therefore maintenance-free and not subject to wear.
Versions
model / series
PMG 20 MO-00
PMG 20 MS-20
PMG 20 MS-21
PMG 20 KX-40
PMG 20 MF-61
PMG 20 MF-62
PMG 20 MF-63
Dielectric constant (ɛ<sub>R</sub>) of medium
MS:
≥ 2.1
KX:
≥ 1.8
MF:
≥ 2.1
Operating temperature range
Medium:
-40/+300 °C
Flange:
-40/+85 °C
Ambient:
-30/+70 °C
Process pressure
MS:
Max. 100 bar
KX:
Max. 100 bar
MF:
Max. 10 bar
Process connection
G1B, Stainless steel 316 Ti
Supply voltage
DC 18 – 36 V
Output signal
4–20 mA/HART, 2-wire
Material
Probe head:
Aluminium die cast
Probe
MS:
Stainless steel 316 Ti
KX:
Stainless steel 316 Ti
MF:
Stainless steel 316 L
Degree of protection
IP67 (EN 60529)
Electrical connection
Cable gland M12 x 1.5

Options

  • Other process connections
  • FEP/PFA coatings